Cisco UCS B200 M5 Blade Server Spec Sheet (2024)

Spec Sheet

Cisco UCS B200 M5 Blade Server

CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV E.03 SEPTEMBER 28, 2021 WWW.CISCO.COM OVERVIEW ...... 3 DETAILED VIEWS ...... 4 BASE SERVER STANDARD CAPABILITIES and FEATURES ...... 5 CONFIGURING the SERVER ...... 7 STEP 1 CHOOSE BASE SERVER SKU ...... 8 UCS B200 Ready2Ship Program ...... 9 STEP 2 CHOOSE CPU(S) ...... 10 STEP 3 CHOOSE MEMORY ...... 15 STEP 4 CHOOSE MLOM ADAPTER ...... 21 STEP 5 CHOOSE SOFTWARE ...... 23 STEP 6 CHOOSE OPTIONAL REAR MEZZANINE ADAPTERS (VIC, NVMe or GPU) ...... 24 STEP 7 CHOOSE OPTIONAL FRONT MEZZANINE ADAPTER ...... 26 STEP 8 CHOOSE OPTIONAL DRIVES ...... 28 STEP 9 CHOOSE OPTIONAL SECURE DIGITAL CARDS or M.2 DRIVES ...... 33 STEP 10 CHOOSE OPTIONAL TRUSTED PLATFORM MODULE ...... 36 STEP 11 CHOOSE OPTIONAL INTERNAL USB 3.0 DRIVE ...... 37 STEP 12 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARE ...... 38 STEP 13 CHOOSE OPTIONAL OPERATING SYSTEM MEDIA KIT ...... 42 STEP 14 CHOOSE SERVICE and SUPPORT LEVEL ...... 43 SUPPLEMENTAL MATERIAL ...... 49 SPARE PARTS ...... 55 UPGRADING or REPLACING CPUs ...... 63 UPGRADING or REPLACING MEMORY ...... 64 DISCONTINUED EOL PRODUCTS ...... 66 TECHNICAL SPECIFICATIONS ...... 74

1 Cisco UCS B200 M5 Blade Server OVERVIEW

OVERVIEW

Delivering performance, versatility and density without compromise, the Cisco UCS B200 M5 Blade Server addresses the broadest set of workloads, from IT and web infrastructure through distributed database.

The enterprise-class Cisco UCS B200 M5 blade server extends the capabilities of Cisco’s Unified Computing System portfolio in a half-width blade form factor.

The Cisco UCS B200 M5 includes support for the following:

■ 2nd Generation Intel® Xeon® Scalable Processors. ■ 2933-MHz DDR4 memory DIMMs. ■ 128 GB, 256 GB, 512 GB Intel® Optane™ Persistent Memory Modules (PMEM). ■ Up to 9 TB of memory is available if the memory slots are populated as follows: — 12 x 256 GB DDR4 DIMMs — 12 x 512 GB PMEMs

Figure 1 Cisco UCS B200 M5 Blade Server

Cisco UCS B200 M5 Blade Server 3 DETAILED VIEWS

DETAILED VIEWS

Blade Server Front View Figure 2 is a detailed front view of the Cisco UCS B200 M5 Blade Server.

Figure 2 Blade Server Front View

4 5 306058

1 2 3 6 7 8 9 10 11 306058

1 Asset pull tag 7 Network link status Each server has a plastic tag that pulls out of the front panel. The tag contains the server serial number as well as the product ID (PID) and version ID (VID). The tag also allows you to add your own asset tracking label without interfering with the intended air flow.

2 Blade ejector handle 8 Blade health LED

3 Ejector captive screw 9 Console connector1

4 Drive bay 1 10 Reset button access

5 Drive bay 2 11 Locator button and LED

6 Power button and LED

Notes: 1. A KVM I/O cable plugs into the console connector, and can be ordered as a spare. The KVM I/O cable in included with every Cisco UCS 5100 Series blade server chassis accessory kit.

4 Cisco UCS B200 M5 Blade Server BASE SERVER STANDARD CAPABILITIES and FEATURES

BASE SERVER STANDARD CAPABILITIES and FEATURES

Table 1 lists the capabilities and features of the base server. Details about how to configure the server for a listed feature or capability (for example, number of processors, disk drives, or amount of memory) are provided in CONFIGURING the SERVER on page 7

Table 1 Capabilities and Features

Capability/Feature Description

Chassis The UCS B200 M5 Blade Server mounts in a Cisco UCS 5108 Series blade server chassis or UCS Mini blade server chassis.

CPU One or two 2nd Generation Intel® Xeon® scalable family CPUs. Also note that the B200 M5 Blade Server BIOS inherently enables support for Intel Advanced Encryption Standard New Instructions (AES-NI) and does not have an option to disable this feature.

Chipset Intel® C621 series chipset (Lewisburg)

Memory ■ 24 total DIMM slots ■ Support for Advanced ECC ■ Support for registered ECC DIMMs (RDIMMs) ■ Support for load-reduced DIMMs (LR DIMMs) ■ Support for through-silicon via DIMMs (TSV DIMMs) ■ Support for Persistent DIMMs (PMEMs) ■ Up to 3072 GB DDR4 DIMM memory capacity (24 x 128 GB DIMMs) ■ Up to 9 TB memory with a mix of DIMMs and PMEMs • 12 x 256 GB DIMMs • 12 x 512 GB PMEMs

Modular LOM One modular LOM (mLOM) connector at the rear of the blade for a Cisco mLOM VIC adapter, which provides Ethernet or Fibre Channel over Ethernet (FCoE) connectivity

Mezzanine Adapters One rear mezzanine connector for various types of Cisco mezzanine adapters (Rear) ■ Cisco Mezzanine VIC Adapter, or ■ Cisco Mezzanine Port Expander, or ■ Cisco Mezzanine NVMe Storage Adapter, or ■ Cisco Mezzanine nVIDIA P6 GPU (can also be placed in front connector)

Mezzanine Adapters One front mezzanine connector for (Front) ■ Cisco FlexStorage controller with drive bays, or ■ Cisco Mezzanine nVIDIA P6 GPU (can also be placed in rear connector) NOTE: No front GPUs are allowed with CPUs that dissipate greater than 165 W.

Cisco UCS B200 M5 Blade Server 5 BASE SERVER STANDARD CAPABILITIES and FEATURES

Table 1 Capabilities and Features (continued)

Capability/Feature Description

Storage controller For the front mezzanine connector: ■ Cisco FlexStorage 12G RAID controller with drive bays ■ Cisco FlexStorage 12G RAID controller with 2GB Cache with drive bays ■ Cisco FlexStorage NVMe Passthrough controller with drive bays (you can also have an NVMe storage adapter in the rear mezzanine connector at the same time)

Storage devices Up to two optional, front-accessible, hot-swappable, 2.5-inch small form factor (SFF) drive slots. Choice of: ■ 10K RPM or 15K RPM hard disk drives (HDD) ■ Enterprise performance or enterprise value solid state drives (SSD) ■ High or medium endurance NVMe Drives Internal mini-storage modules that can accommodate either: ■ Up to two SD modules (32 GB, 64 GB, or 128 GB supporting RAID 1, or ■ Up to two M.2 SATA drives (240 GB or 960 GB) supported by LSI SW RAID Internal UCS 3.0 Port that can accommodate a Cisco 16 GB USB drive

Video The Cisco Integrated Management Controller (CIMC) provides video using the Matrox G200e video/graphics controller:

■ Integrated 2D graphics core with hardware acceleration ■ 512MB total DDR4 memory, with 16MB dedicated to Matrox video memory ■ Supports display resolutions up to 1920 x 1200 16bpp @ 60Hz ■ High-speed integrated 24-bit RAMDAC ■ Single lane PCI-Express host interface running at Gen 1 speed

Interfaces One KVM console connector on the front panel

Power subsystem Integrated in the Cisco UCS 5108 blade server chassis

Fans Integrated in the Cisco UCS 5108 blade server chassis.

Integrated management The built-in Cisco Integrated Management Controller (CIMC) GUI or CLI processor interface enables monitoring of server inventory, health, and system event logs

ACPI Advanced Configuration and Power Interface (ACPI) 4.0 Standard Supported.

6 Cisco UCS B200 M5 Blade Server CONFIGURING the SERVER

CONFIGURING the SERVER

Follow these steps to configure the Cisco UCS B200 M5 Blade Server:

■ STEP 1 CHOOSE BASE SERVER SKU, page 8 ■ STEP 2 CHOOSE CPU(S), page 10 ■ STEP 3 CHOOSE MEMORY, page 15 ■ STEP 4 CHOOSE MLOM ADAPTER, page 21 ■ STEP 5 CHOOSE SOFTWARE, page 23 ■ STEP 6 CHOOSE OPTIONAL REAR MEZZANINE ADAPTERS (VIC, NVMe or GPU), page 24 ■ STEP 7 CHOOSE OPTIONAL FRONT MEZZANINE ADAPTER, page 26 ■ STEP 8 CHOOSE OPTIONAL DRIVES, page 28 ■ STEP 9 CHOOSE OPTIONAL SECURE DIGITAL CARDS or M.2 DRIVES, page 34 ■ STEP 10 CHOOSE OPTIONAL TRUSTED PLATFORM MODULE, page 37 ■ STEP 11 CHOOSE OPTIONAL INTERNAL USB 3.0 DRIVE, page 38 ■ STEP 12 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARE, page 39 ■ STEP 13 CHOOSE OPTIONAL OPERATING SYSTEM MEDIA KIT, page 43 ■ STEP 14 CHOOSE SERVICE and SUPPORT LEVEL, page 44

Cisco UCS B200 M5 Blade Server 7 CONFIGURING the SERVER

STEP 1 CHOOSE BASE SERVER SKU

Verify the product ID (PID) of the server as shown in Table 2.

Table 2 PID of the Base UCS B200 M5 Blade Server

Product ID (PID) Description

UCSB-B200-M5 UCS B200 M5 Blade Server without CPU, memory, drive bays, HDD, VIC adapter, or mezzanine adapters (ordered as a blade chassis option)

UCSB-B200-M5-U UCS B200 M5 Blade Server without CPU, memory, drive bays, HDD, VIC adapter, or mezzanine adapters (ordered standalone)

UCSB-B200-M5-CH DISTI: UCS B200 M5 Blade Server without CPU, memory, drive bays, HDD, VIC adapter, or mezzanine adapters

UCSB-10-PK-M5BLADE MULTI: 10-PK B200 M5 W/BLANKING PANELS, PACKAGING KIT

A base Cisco UCS B200 M5 blade server ordered in Table 2 does not include any components or option They must be selected during product ordering.

Please follow the steps on the following pages to order components such as the following, which are required in a functional blade:

• CPUs • Memory • Cisco FlexStorage RAID controller with drive bays (or blank, for no local drive support) • Drives • Cisco adapters (such as the VIC 1340,VIC 1380, VIC 1440, VIC 1480, or Port Expander) • Cisco UCS NVMe Flash Storage Adapters or GPUs.

8 Cisco UCS B200 M5 Blade Server UCS B200 Ready2Ship Program

UCS B200 Ready2Ship Program

5 Ready2Ship Blade Configurations ■ Most popular ■ Shipped within 5 days ■ Standard Pricing

Table 3 shows the UCS B200M5 Ready2Ship Configuration

Table 3 available configuration

Product ID (PID) Description

UCSB-B200M5-RSV1A Qty 1 B200 M5 Blade Server with Qty 2 Intel 6252 , Qty 12 64GB Memory, Qty 1 1340 MLOM, Qty 1 M2 240GB HW RAID

UCSB-B200M5-RSV1B Qty 1 B200 M5 Blade Server with Qty 2 Intel 6226R , Qty 12 64GB Memory, Qty 1 1440 MLOM, Qty 1 M2 240GB HW RAID

UCSB-B200M5-RSV1C Qty 1 B200 M5 Blade Server with Qty 2 Intel 6248 , Qty 12 32GB Memory, Qty 1 1340 MLOM, Qty 1 M2 240GB HW RAID

UCSB-B200M5-RSV1D Qty 1 B200 M5 Blade Server with Qty 2 Intel 6254 , Qty 12 64GB Memory, Qty 1 1340 MLOM, Qty 1 M2 240GB HW RAID

UCSB-B200M5-RSV1E Qty 1 B200 M5 Blade Server with Qty 2 Intel 5218R , Qty 12 64GB Memory, Qty 1 1440 MLOM, Qty 1 M2 240GB HW RAID

NOTE: ■ 3-5 days is Business days, does not include delivery time and is based on receipt of final Partner PO; Subject to parts in stock at time of final PO ■ Only orderable through Authorized Build To Order (BTO) Distributors – Tech Data US.

Cisco UCS B200 M5 Blade Server 9 UCS B200 Ready2Ship Program

STEP 2 CHOOSE CPU(S)

The standard CPU features are:

■ 2nd Generation Intel® Xeon® scalable processor family CPUs. ■ Intel® C621 series chipset ■ Up to 28 cores per processor, for a total of up to 56 cores per server ■ Please refer to the notes below on ambient inlet temperature requirements and allowed Mezz Card Configuration due to CPU thermal requirements.

NOTE: The CPUs designated as Ix2xx are 2nd Generation Intel® Xeon® scalable processor family CPUs.

Select CPUs from Tabl e 4.

Table 4 Available CPUs

Highest DDR4 Clock Cache Power UPI2 Links DIMM Clock Product ID (PID)1 Freq Size Cores Workload (W) (GT/s) Support (GHz) (MB) (MHz)3 Cisco Recommended Processors 4, 5 (2nd Generation Intel® Xeon® Processors) UCS-CPU-I8276 2.2 165 38.50 28 3 x 10.4 2933 Oracle, SAP UCS-CPU-I8260 2.4 165 35.75 24 3 x 10.4 2933 Microsoft Azure Stack UCS-CPU-I6262V 1.9 135 33.00 24 3 x 10.4 2400 Virtual Server infrastructure or VSI UCS-CPU-I6248R 3.0 205 35.75 24 2 x 10.4 2933 UCS-CPU-I6248 2.5 150 27.50 20 3 x 10.4 2933 VDI, Oracle, SQL, Microsoft Azure Stack UCS-CPU-I6238R 2.2 165 38.50 28 2 x 10.4 2933 Oracle, SAP (2-Socket TDI only), Microsoft AzureStack UCS-CPU-I6238 2.1 140 30.25 22 3 x 10.4 2933 SAP UCS-CPU-I6234 3.3 130 24.75 8 3 x 10.4 2933 Oracle, SAP UCS-CPU-I6230R 2.1 150 35.75 26 2 x 10.4 2933 Virtual Server Infrastructure, Data Protection, Big Data, Splunk, Microsoft AzureStack UCS-CPU-I6230 2.1 125 27.50 20 3 x 10.4 2933 Big Data, Virtualization UCS-CPU-I5220R 2.2 150 35.75 24 2 x 10.4 2666 Virtual Server Infrastructure, Splunk, Microsoft Azure Stack UCS-CPU-I5220 2.2 125 24.75 18 2 x 10.4 2666 HCI

10 Cisco UCS B200 M5 Blade Server UCS B200 Ready2Ship Program

Table 4 Available CPUs (continued)

Highest DDR4 Clock Cache Power UPI2 Links DIMM Clock Product ID (PID)1 Freq Size Cores Workload (W) (GT/s) Support (GHz) (MB) (MHz)3 UCS-CPU-I5218R 2.1 125 27.50 20 2 x 10.4 2666 Virtual Server Infrastructure, Data Protection, Big Data, Splunk, Scale-out Object Storage, Microsoft AzureStack UCS-CPU-I5218 2.3 125 22.00 16 2 x 10.4 2666 Virtualization, Microsoft Azure Stack, Splunk, Data Protection UCS-CPU-I4216 2.1 100 22.00 16 2 x 9.6 2400 Data Protection, Scale Out Storage UCS-CPU-I4214R 2.4 100 16.50 12 2 x 9.6 2400 Data Protection, Splunk, Scale-out Object Storage, Microsoft AzureStack UCS-CPU-I4214 2.2 85 16.50 12 2 x 9.6 2400 Data Protection, Scale Out Storage UCS-CPU-I4210R 2.4 100 13.75 10 2 x 9.6 2400 Virtual Server Infrastructure, Data Protection, Big Data, Splunk UCS-CPU-I4210 2.2 85 13.75 10 2 x 9.6 2400 Virtualization, Big Data, Splunk 8000 Series Processor UCS-CPU-I8280L 2.7 205 38.50 28 3 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I8280 2.7 205 38.50 28 3 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I8276L 2.2 165 38.50 28 3 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I8276 2.2 165 38.50 28 3 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I8270 2.7 205 35.75 26 3 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I8268 2.9 205 35.75 24 3 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I8260Y 2.4 165 35.75 24/2 3 x 10.4 2933 2nd Gen Intel® Xeon® 0/16 UCS-CPU-I8260L 2.3 165 35.75 24 3 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I8260 2.4 165 35.75 24 3 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I8253 2.2 125 22.00 16 3 x 10.4 2933 2nd Gen Intel® Xeon® 6000 Series Processor UCS-CPU-I6262V 1.9 135 33.00 24 3 x 10.4 2400 2nd Gen Intel® Xeon® UCS-CPU-I6258R 2.7 205 35.75 28 2 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I6254 3.1 200 24.75 18 3 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I6252N 2.3 150 35.75 24 3 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I6252 2.1 150 35.75 24 3 x 10.4 2933 2nd Gen Intel® Xeon®

Cisco UCS B200 M5 Blade Server 11 UCS B200 Ready2Ship Program

Table 4 Available CPUs (continued)

Highest DDR4 Clock Cache Power UPI2 Links DIMM Clock Product ID (PID)1 Freq Size Cores Workload (W) (GT/s) Support (GHz) (MB) (MHz)3 UCS-CPU-I6248R 3.0 205 35.75 24 2 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I6248 2.5 150 27.50 20 3 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I6246R 3.4 205 35.75 16 2 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I6246 3.3 165 24.75 12 3 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I6244 3.6 150 24.75 8 3 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I6242R 3.1 205 35.75 20 2 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I6242 2.8 150 22.00 16 3 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I6240R 2.4 165 35.75 24 2 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I6240Y 2.6 150 24.75 18/1 3 x 10.4 2933 2nd Gen Intel® Xeon® 4/8 UCS-CPU-I6240L 2.6 150 24.75 18 3 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I6240 2.6 150 24.75 18 3 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I6238R 2.2 165 38.50 28 2 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I6238L 2.1 140 30.25 22 3 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I6238 2.1 140 30.25 22 3 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I6234 3.3 130 24.75 8 3 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I6230R 2.1 150 35.75 26 2 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I6230N 2.3 125 27.50 20 3 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I6230 2.1 125 27.50 20 3 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I6226R 2.9 150 22.00 16 2 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I6226 2.7 125 19.25 12 3 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I6222V 1.8 115 27.50 20 3 x 10.4 2400 2nd Gen Intel® Xeon® 5000 Series Processor UCS-CPU-I5222 3.8 125 16.50 4 2 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I5220S 2.6 125 19.25 18 2 x 10.4 2666 2nd Gen Intel® Xeon® UCS-CPU-I5220R 2.2 150 35.75 24 2 x 10.4 2666 2nd Gen Intel® Xeon® UCS-CPU-I5220 2.2 125 24.75 18 2 x 10.4 2666 2nd Gen Intel® Xeon® UCS-CPU-I5218R 2.1 125 27.50 20 2 x 10.4 2666 2nd Gen Intel® Xeon® UCS-CPU-I5218B 2.3 125 22.00 16 2 x 10.4 2933 2nd Gen Intel® Xeon® UCS-CPU-I5218N 2.3 105 22.00 16 2 x 10.4 2666 2nd Gen Intel® Xeon® UCS-CPU-I5218 2.3 125 22.00 16 2 x 10.4 2666 2nd Gen Intel® Xeon® UCS-CPU-I5217 3.0 115 11.00 8 2 x 10.4 2666 2nd Gen Intel® Xeon® UCS-CPU-I5215L 2.5 85 13.75 10 2 x 10.4 2666 2nd Gen Intel® Xeon® UCS-CPU-I5215 2.5 85 13.75 10 2 x 10.4 2666 2nd Gen Intel® Xeon® 4000 Series Processor

12 Cisco UCS B200 M5 Blade Server UCS B200 Ready2Ship Program

Table 4 Available CPUs (continued)

Highest DDR4 Clock Cache Power UPI2 Links DIMM Clock Product ID (PID)1 Freq Size Cores Workload (W) (GT/s) Support (GHz) (MB) (MHz)3 UCS-CPU-I4216 2.1 100 22.00 16 2 x 9.6 2400 2nd Gen Intel® Xeon® UCS-CPU-I4215R 3.2 130 11.00 8 2 x 9.6 2400 2nd Gen Intel® Xeon® UCS-CPU-I4215 2.5 85 11.00 8 2 x 9.6 2400 2nd Gen Intel® Xeon® UCS-CPU-I4214Y 2.4 85 16.50 12 2 x 9.6 2400 2nd Gen Intel® Xeon® UCS-CPU-I4214R 2.2 105 16.75 12/1 2 x 9.6 2400 2nd Gen Intel® Xeon® 0/8 UCS-CPU-I4214 2.2 85 16.50 12 2 x 9.6 2400 2nd Gen Intel® Xeon® UCS-CPU-I4210R 2.4 100 13.75 10 2 x 9.6 2400 2nd Gen Intel® Xeon® UCS-CPU-I4210 2.2 85 13.75 10 2 x 9.6 2400 2nd Gen Intel® Xeon® UCS-CPU-I4208 2.1 85 11.00 8 2 x 9.6 2400 2nd Gen Intel® Xeon® 3000 Series Processor UCS-CPU-I3206R 1.9 85 11.00 8 2 x 9.6 2133 2nd Gen Intel® Xeon® UCS-CPU-I3204 1.9 85 8.25 6 2 x 9.6 2133 2nd Gen Intel® Xeon®

Notes: 1. For additional details on ambient temperature limitation or configuration restrictions see Tabl e 3a Page on 15 2. UPI = Ultra Path Interconnect 3. If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU, the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock. 4. For details on memory support for processor classes and CPU modes, see Memory Support for CPU Classes and CPU Modes on page 54 5. For 2nd Generation Intel® Xeon® Scalable Processors, UCSM 4.0(4) software release is required.

CAUTION: In Table 5, systems configured with the processors shown must adhere to the ambient inlet temperature thresholds specified. If not, a fan fault or executing workloads with extensive use of heavy instructions sets such as Intel® Advanced Vector Extensions 512 (Intel® AVX-512) may assert thermal and/or performance faults with an associated event recorded in the System Event Log (SEL). Ta bl e 5 lists ambient temperature limitations below 35° C (95° F) and configuration restrictions to ensure proper cooling and avoid excessive processor throttling, which may impact system performance.

Cisco UCS B200 M5 Blade Server 13 UCS B200 Ready2Ship Program

Table 5 Ambient Temperature and Configuration Restrictions

Ambient Processor Thermal Configuration CPU PID Blade Slot Temperature Design Power (TDP) Restriction Limitation

UCS-CPU-I8260Y UCS-CPU-I6252N Any Y or N SKUs Any UCS-CPU-I6240Y UCS-CPU-I6230N

UCS-CPU-I8280L UCS-CPU-I8280 UCS-CPU-I8270 UCS-CPU-I8268 32oC (90o F) 200 W or 205 W UCS-CPU-8180M Any UCS-CPU-8180 UCS-CPU-8168 UCS-CPU-I6254 UCS-CPU-6154 Front Mezzanine GPU UCS-CPU-I6246 Frequency optimized UCS-CPU-I6244 Any 150/165/125 W UCS-CPU-I5222

UCS-CPU-I6258R UCS-CPU-I6248R 1 through 7 o o UCS-CPU-6246R 25 C (77 F) UCS-CPU-6242R 205W R SKUs UCS-CPU-I6258R 8

UCS-CPU-I6248R UCS-CPU-6246R 8 22o C (72o F) UCS-CPU-6242R

Supported Configurations

(1) One-CPU Configuration

— Choose one CPU from any one of the rows of Table 4 Available CPUs, page 10

(2) Two-CPU Configuration

— Choose two identical CPUs from any one of the rows of Table 4 Available CPUs, page 10

NOTE: See CHOOSE MEMORY on page 15 for details on the compatibility of CPUs and DIMM speeds.

14 Cisco UCS B200 M5 Blade Server UCS B200 Ready2Ship Program

STEP 3 CHOOSE MEMORY

The available memory for the B200 M5 is as follows:

■ Clock speed: 2933 or 2666 MHz depending on CPU type ■ Ranks per DIMM: 1, 2, 4, or 8 ■ Operational voltage: 1.2 V ■ Registered ECC DDR4 DIMMS (RDIMMs), Load-reduced DIMMs (LRDIMMs), through-silicon via DIMMs (TSV DIMMs), or Intel® Optane™ Persistent Memory (PMEMs).

Memory is organized with six memory channels per CPU, with up to two DIMMs per channel, as shown in Figure 3.

Figure 3 B200 M5 Memory Organization

24 DIMMs, 6 Memory channels per CPU, up to 2 DIMMs per channel

Cisco UCS B200 M5 Blade Server 15 UCS B200 Ready2Ship Program

Choose DIMMs and Memory Mirroring

Select the memory configuration and whether or not you want the memory mirroring option. The supported memory DIMMs, PMEMs, PMEM Memory Mode, and the mirroring option are listed in Table 6.

Table 6 Available DDR4 DIMMs and PMEMs

Ranks Product ID (PID) PID Description Voltage /DIMM

2933-MHz DIMMs UCS-ML-256G8RT-H 256 GB DDR4-2933-MHz LRDIMM/8Rx4 1.2 V UCS-ML-128G4RT-H 128 GB DDR4-2933-MHz LRDIMM/4Rx4 1.2 V 4 UCS-ML-X64G4RT-H 64 GB DDR4-2933-MHz LRDIMM/4Rx4 1.2 V 4 UCS-MR-X64G2RT-H 64 GB DDR4-2933-MHz RDIMM/2Rx4 1.2 V 2 UCS-MR-X32G2RT-H 32 GB DDR4-2933-MHz RDIMM/2Rx4 1.2 V 2 UCS-MR-X16G1RT-H 16 GB DDR4-2933-MHz RDIMM/1Rx4 1.2 V 1 Intel® Optane™ Persistent Memory Product UCS-MP-128GS-A0 Intel® Optane™ Persistent Memory, 128GB, 2666-MHz UCS-MP-256GS-A0 Intel® Optane™ Persistent Memory, 256GB, 2666-MHz UCS-MP-512GS-A0 Intel® Optane™ Persistent Memory, 512GB, 2666-MHz Intel® Optane™ Persistent Memory Product Operational Modes UCS-DCPMM-AD App Direct Mode UCS-DCPMM-MM Memory Mode Memory Mirroring Option1 N01-MMIRROR Memory mirroring option

Notes: 1. For Memory Configuration and Mirroring, please refer to Memory Configuration and Mirroring on page 51 and Memory Support for CPU Classes and CPU Modes on page 54.

16 Cisco UCS B200 M5 Blade Server UCS B200 Ready2Ship Program

NOTE: ■ Based on the Intel tech spec, the below DIMMs be used with the 1st Generation Intel® Xeon® scalable processor family CPUs and the 2nd Generation Intel® Xeon® scalable processor family CPUs UCS-MR-X16G1RT-H UCS-MR-X32G2RT-H UCS-ML-X64G4RT-H ■ Based on the Intel tech spec, the below DIMMs can be used only with 2nd Generation Intel® Xeon® scalable processor family CPUs, not with Intel® Xeon® scalable processor family CPUs. UCS-ML-256G8RT-H UCS-ML-128G4RT-H UCS-MR-X64G2RT-H

Memory Configurations Features and Modes System speed is dependent on the CPU DIMM speed support. Refer to Available CPUs on page 10 for DIMM speeds.

■ The B200 M5 server supports the following memory reliability, availability, and serviceability (RAS) modes: — Independent Channel Mode — Mirrored Channel Mode ■ Below are the system level RAS Mode combination limitations: — Mixing of Independent and Lockstep channel mode is not allowed per platform. — Mixing of Non-Mirrored and Mirrored mode is not allowed per platform. — Mixing of Lockstep and Mirrored mode is not allowed per platform. — Do not mix RDIMMs, LRDIMMs, or TSV-RDIMMs. — Single-rank DIMMs can be mixed with dual-rank DIMMs in the same channel ■ For best performance, observe the following: — DIMMs with different timing parameters can be installed on different slots within the same channel, but only timings that support the slowest DIMM will be applied to all. As a consequence, faster DIMMs will be operated at timings supported by the slowest DIMM populated. — When one DIMM is used, it must be populated in DIMM slot 1 (farthest away from the CPU) of a given channel. — When single- or dual-rank DIMMs are populated in two DIMMs per channel (2DPC) configurations, always populate the higher number rank DIMM first (starting from the farthest slot). For a 2DPC example, first populate with dual-rank DIMMs in DIMM slot 1. Then populate single-rank DIMMs in DIMM 2 slot. ■ DIMMs for CPU 1 and CPU 2 (when populated) must always be configured identically. ■ Cisco memory from previous generation servers (DDR3 and DDR4) is not compatible with the UCS B200 M5 Blade.

Cisco UCS B200 M5 Blade Server 17 UCS B200 Ready2Ship Program

■ Memory can be configured in any number of DIMMs as pairs, although for optimal performance, see the document at the following link: https://www.cisco.com/c/dam/en/us/products/collateral/servers-unified-computing/ucs- c-series-rack-servers/memory-guide-c220-c240-b200-m5.pdf. ■ For additional information, refer to Memory Configuration and Mirroring on page 51. ■ For detailed Intel PMEM configurations, refer to the Cisco UCS B200 M5 Server Installation Guide

See Table 7 and Table 8 for information on DIMM speeds with Intel Scalable Processors.

Table 7 2933-MHz DIMM Memory Speeds with 2nd Generation Intel® Xeon® Scalable Processors

DIMM and CPU LRDIMM RDIMM RDIMM RDIMM LRDIMM Frequencies DPC (4Rx4)- (2Rx4) - (2Rx4) - (1Rx4) - (4Rx4) - (MHz) 128 GB 64 GB (MHz) 32 GB (MHz) 16 GB (MHz) 64 GB (MHz) (MHz)

1.2 V 1.2 V 1.2 V 1.2 V 1.2 V

DIMM = 2933 1DPC 2933 2933 2933 2933 2933 CPU = 2933 2DPC 2933 2933 2933 2933 2933

DIMM = 2933 1DPC 2666 2666 2666 2666 2666 CPU = 2666 2DPC 2666 2666 2666 2666 2666

DIMM = 2933 1DPC 2400 2400 2400 2400 2400 CPU = 2400 2DPC 2400 2400 2400 2400 2400

DIMM = 2933 1DPC 2133 2133 2133 2133 2133 CPU = 2133 2DPC 2133 2133 2133 2133 2133

Table 8 2666-MHz DIMM Memory Speeds with Intel® Xeon® Scalable Processors

TSV- TSV- LRDIMM RDIMM LRDIMM DIMM and CPU RDIMM RDIMM (4Rx4) - (2Rx4) - (2Rx4) - Frequencies DPC (8Rx4) - (4Rx4) - 64 GB 32 GB 32 GB (MHz) 128 GB 64 GB (MHz) (MHz) (MHz) (MHz) (MHz)

1.2 V 1.2 V 1.2 V 1.2 V 1.2 V

DIMM = 2666 1DPC 2666 2666 2666 2666 2666 CPU = 2666 2DPC 2666 2666 2666 2666 2666

DIMM = 2666 1DPC 2400 2400 2400 2400 2400 CPU = 2400 2DPC 2400 2400 2400 2400 2400

18 Cisco UCS B200 M5 Blade Server UCS B200 Ready2Ship Program

Table 8 2666-MHz DIMM Memory Speeds with Intel® Xeon® Scalable Processors

TSV- TSV- LRDIMM RDIMM LRDIMM DIMM and CPU RDIMM RDIMM (4Rx4) - (2Rx4) - (2Rx4) - Frequencies DPC (8Rx4) - (4Rx4) - 64 GB 32 GB 32 GB (MHz) 128 GB 64 GB (MHz) (MHz) (MHz) (MHz) (MHz)

DIMM = 2666 1DPC 2133 2133 2133 2133 2133 CPU = 2133 2DPC 2133 2133 2133 2133 2133

See Table 9 for PMEM memory modes.

Table 9 Intel® Optane™ Persistent Memory Modes

Intel® Persistent Memory Modes

App Direct Mode: PMEM operates as a solid-state disk storage device. Data is saved and is non-volatile. Both PMEM and DIMM capacity counts towards CPU tiering (both PMEM and DIMM capacities count towards the CPU capacity limit)

Memory Mode:1 PMEM operates as a 100% memory module. Data is volatile and DRAM acts as a cache for PMEMs. Only PMEM capacity counts towards CPU tiering (only the PMEM capacity counts towards the CPU capacity limit). This is the factory default mode.

Mix Mode: DRAM as cache. Only PMEM capacity counts towards CPU tiering (only the PMEM capacity counts towards the CPU capacity limit).

Notes: 1. For Memory Mode, the Intel-recommended DIMM to PMEM capacity ratio in the same CPU channel is from 1:2 to 1:16. So if you use a 128 GB DIMM in a channel, you could use a 512 GB PMEM for a 1:4 capacity ratio. If you use a 32 GB DIMM in a channel, you could use a 512 GB PMEM for a 1:16 capacity ratio. There are several other combinations possible

Cisco UCS B200 M5 Blade Server 19 UCS B200 Ready2Ship Program

See Table 10 for how to populate combinations of DIMMs and PMEMs.

Table 10 2 nd Generation Intel® Xeon® Scalable Processor DIMM and PMEM1 Physical Configurations (dual socket)

DIMM to CPU 1 PMEM Count

iMC1 iMC0

Channel 2 Channel 1 Channel 0 Channel 2 Channel 1 Channel 0

F2 F1 E2 E1 D2 D1 C2 C1 B2 B1 A2 A1

6 to 2 DIMM DIMM PMEM DIMM DIMM DIMM PMEM DIMM

6 to 4 DIMM PMEM DIMM PMEM DIMM DIMM PMEM DIMM PMEM DIMM

6 to 6 PMEM DIMM PMEM DIMM PMEM DIMM PMEM DIMM PMEM DIMM PMEM DIMM

DIMM to PMEM CPU 2 Count

iMC1 iMC0

Channel 2 Channel 1 Channel 0 Channel 2 Channel 1 Channel 0

M2 M1 L2 L1 K2 K1 J2 J1 H2 H1 G2 G1

6 to 2 DIMM DIMM PMEM DIMM DIMM DIMM PMEM DIMM

6 to 4 DIMM PMEM DIMM PMEM DIMM DIMM PMEM DIMM PMEM DIMM

6 to 6 PMEM DIMM PMEM DIMM PMEM DIMM PMEM DIMM PMEM DIMM PMEM DIMM

Notes: 1. All systems must be fully populated with two CPUs when using PMEMs at this time.

NOTE: There are three possible memory configurations for each CPU when combining DIMMs and PMEMs, and the configurations must be the same for each CPU: • 6 DIMMs and 2 PMEMs, or • 6 DIMMs and 4 PMEMs, or • 6 DIMMs and 6 PMEMs

For detailed Intel PMEM configurations, refer to

Cisco UCS B200 M5 Server Installation Guide

For detailed DIMM/PMEM informations, refer to

Cisco UCS C220/C240/B200 M5 Memory Guide

20 Cisco UCS B200 M5 Blade Server UCS B200 Ready2Ship Program

STEP 4 CHOOSE MLOM ADAPTER

The UCS B200 M5 must be ordered with a Cisco VIC mLOM Adapter. The adapter can operate in a single-CPU or dual-CPU configuration. Table 12 shows available mLOM adapter choices.

Table 11 mLOM Adapters

Product ID (PID) Description Connection type

UCSB-MLOM-40G-04 Cisco UCS VIC 1440 modular LOM for blade servers mLOM

UCSB-MLOM-40G-03 Cisco UCS VIC 1340 modular LOM for blade servers mLOM

Table 12 Aggregate Bandwidth with mLOM Only configuration

mLOM Fabrics Extenders in UCS 5108 blade chassis Fabric Interconnects Support Only Aggregate Bandwidth (Gb/s)

2x 2408 2x 2x2208XP 2x 2204XP 2 x 2 x 2 x 2 x 2 x 2304V2 62xx 6324 6332 6332-16UP 6400

VIC 1440 401 401 401 20 Yes Yes Yes Yes Yes mLOM (20 Gb/s)

VIC 1340 401 401 401 20 Yes Yes Yes Yes Yes mLOM (20 Gb/s)

Notes: 1. These configurations implement two 2x10 Gbps port-channels

Cisco developed 1300 and 1400 Series Virtual Interface Cards (VICs) to provide flexibility to create multiple NIC and HBA devices.The VIC features are listed here:

• VICs include enhancements including network overlay offload support. • Two Converged Network Adapter (CNA) ports, supporting both Ethernet and FCoE • Delivers up to 80 Gbps total I/O throughput to the server • VIC supports either max dual 4x10Gbps Unified I/O ports or 2x40 (native) Gbps Unified I/O ports • Supports up to 256 fully functional unique and independent PCIe adapters and interfaces • Provides virtual machine visibility from the physical network and a consistent network operations model for physical and virtual servers • Supports customer requirements for a wide range of operating systems and hypervisors

The mLOM VIC on the UCS B200 M5 enables connectivity to the Fabric Interconnect either through the Fabric Extender (FEX) or directly using the UCS 6324 Fabric Connector (UCS Mini) on the UCS 5108 Blade Chassis.

Cisco UCS B200 M5 Blade Server 21 UCS B200 Ready2Ship Program

The supported Fabric Extenders for the B200 M5 blades are

— Cisco UCS 2408 Fabric Extender — Cisco UCS 2208XP Fabric Extender — Cisco UCS 2204XP Fabric Extender — Cisco UCS 2304V2 Fabric Extender

The supported Fabric Interconnects for the B200 M5 blades are

— Cisco UCS 6248UP Fabric Interconnect — Cisco UCS 6296UP Fabric Interconnect — Cisco UCS 6332 Fabric Interconnect — Cisco UCS 6332-16UP Fabric Interconnect — Cisco UCS 6454 Fabric Interconnect — Cisco UCS 64108 Fabric Interconnect

The recommended UCS Manager (UCSM) release for the B200 M5 is UCSM 3.2(2), due to support of higher wattage CPUs. The Cisco UCS 64xx Fabric Interconnect and/or VIC 1440 requires UCSM 4.0(1) or greater.

22 Cisco UCS B200 M5 Blade Server UCS B200 Ready2Ship Program

STEP 5 CHOOSE SOFTWARE

A UCSM software version needs to be selected for the standalone UCS B200 M5 Blade PID (UCSB-B200-M5-UPG).

NOTE: • This is a new mandatory option for standalone blades starting with the UCS B200 M5. • When the UCS B200 M5 is configured inside of a chassis in the CCW ordering tool, the UCSM software version is selected at the chassis level. The software option will not be available under the UCS B200 M5 in that case. • The recommended UCS releases for the UCS B200 M5 are UCSM 3.2(2) and UCSM 4.0. These releases support higher wattage CPUs. FI 6454 and/or VIC 1400 require release UCSM 4.0(1) or greater.

Choose one software PID from Table 13.

Table 13 Available UCSM Software

Product ID (PID) Product Description Software Version

N20-FW016 UCS 5108 Blade Chassis FW Package 4.0 UCSM 4.0

N20-FW017 UCS 5108 Blade Chassis FW Package 4.1 UCSM 4.1

N20-FW018 UCS 5108 Blade Chassis FW Package 4.2 UCSM 4.2

Cisco UCS B200 M5 Blade Server 23 UCS B200 Ready2Ship Program

STEP 6 CHOOSE OPTIONAL REAR MEZZANINE ADAPTERS (VIC, NVMe or GPU)

The UCS B200 M5 has one rear mezzanine adapter connector. The UCS B200 M5 can be ordered with or without a rear mezzanine adapter. Refer to Table 14 Available Rear Mezzanine Adapters for supported adapters.

Table 14 Available Rear Mezzanine Adapters

Product ID(PID) PID Description CPUs Required Connector Type

Port Expander Card for VIC This is a hardware option to enable an additional 4 ports of the VIC 1340, bringing the total capability of the VIC 1340 to a dual native 40G interface or a dual 4 x 10 GbE port-channeled interface, respectively. UCSB-MLOM-PT-01 Cisco UCS Port Expander Card for VIC 1 or 2 CPUs Rear Mezzanine

Cisco VIC Card

UCSB-VIC-M84-4P Cisco UCS VIC 1480 mezzanine adapter 2 CPUs required Rear Mezzanine

UCSB-VIC-M83-8P Cisco UCS VIC 1380 mezzanine adapter 2 CPUs required Rear Mezzanine

Cisco GPU Rear

UCSB-GPU-P6-R1 NVIDIA GRID P6 Rear Mezzanine 2 CPUs required Rear Mezzanine

Notes: 1. For GPU P6, maximum cards per node supported is two.

Supported Configurations

— Requires an mLOM (either VIC 1340 or VIC 1440) — You cannot mix a 1340 with a 1480 or a 1440 and a 1380)

See Table 15 for aggregate bandwidths with various rear mezzanine cards installed.

24 Cisco UCS B200 M5 Blade Server UCS B200 Ready2Ship Program

Table 15 Aggregate Bandwidth with Rear Mezzanine Cards Installed

Rear Mezz IO Modules in UCS5108 blade chassis Fabric Interconnects Support Adapter Aggregate Bandwidth (Gb/s)

2x 2x 2x 2x 2 x 2 x 2 x 2 x 2 x 2408 2304V 2208XP 2204XP 62xx 6324 6332 6332-16UP 6400 2

Port 802 801 802 403 Yes Yes Yes Yes Yes Expander+ (40Gbps) VIC 1340

Port 804 801,5 Not Not No No Yes Yes Yes Expander Supported Supported + VIC 1440

VIC 1380 806 806 806 40 Yes Yes Yes Yes Yes mezz (40Gbps)

VIC 1480 806 806 806 40 Yes Yes Yes Yes Yes mezz (40Gbps)

Flash Card 403 403 403 20 Yes Yes Yes Yes Yes (20Gbps)

GPU 403 403 403 20 Yes Yes Yes Yes Yes (20Gbps)

Notes: 1. Uses a dual native 40G interface 2. Two 4x10Gbps port-channeled 3. Two 2x10Gbps port-channeled 4. Supported starting with UCSM 4.1(2). The maximum single-flow is 25 Gbps with an aggregate of 40 Gbps. To avoid IOM/Fabric Extender transient drops due to a speed mismatch of 40 Gbps towards the server and 25 Gbps towards the fabric interconnect (FI), vNIC rate-limiting to 25 Gbps is recommended. 5. If operating in 4x10 mode, bandwidth drops down to 40Gbps (two 2x10 G port-channeled) 6. Four 2x10 Gbps port-channeled

Cisco UCS B200 M5 Blade Server 25 UCS B200 Ready2Ship Program

STEP 7 CHOOSE OPTIONAL FRONT MEZZANINE ADAPTER

The UCS B200 M5 has one front mezzanine connector that can accommodate a storage controller with bays for NVMe drives or a GPU. The UCS B200 M5 can be ordered with or without the front mezzanine adapter. Refer to Table 16 Available Front Mezzanine Adapters.

NOTE: A front GPU cannot be used with CPUs that dissipate greater than 165 W.

Table 16 Available Front Mezzanine Adapters

Product ID(PID) PID Description Connector Type

Storage Controller1 (required for installing local drives in the UCS B200 M5

UCSB-MRAID12G2,3 Cisco FlexStorage 12G SAS RAID controller with drive Front Mezzanine bays

UCSB-MRAID12G-HE4,3 Cisco FlexStorage 12G SAS RAID controller with 2 GB Front Mezzanine flash-backed write cache with drive bays

UCSB-LSTOR-PT5 Cisco FlexStorage NVME Passthrough module with Front Mezzanine HDD cage

UCSB-LSTOR-BK6 Cisco FlexStorage blanking panel without controller Drive Blank or drive bays

Cisco GPU Front

UCSB-GPU-P6-F7 NVIDIA GRID P6 Front Mezzanine Front Mezzanine

Notes: 1. A Storage Controller is required for installing local drives (HDD, SSD, NVMe) on the B200 M5. 2. For hard disk drives (HDDs) or solid-state drives (SSDs), a Cisco FlexStorage 12G SAS RAID Controller is required. 3. The Cisco FlexStorage 12G SAS RAID Controller is based on the LSI 3108 ROC and runs the iMegaRAID software stack. It provides 12 Gbps RAID functionality for SAS/SATA SSD/HDD and has RAID 0, 1 and JBOD support.If supercapacitor needs to be replaced, it can be done so by ordering UCSB-MRAID-SC=. See Installation Document for instructions. 4. The Cisco FlexStorage 12G SAS RAID controller with 2 GB Flash-backed write cache is based on the LSI 3108 ROC and runs the LSI MegaRAID software stack. It provides 12 Gbps RAID Functionality for SAS/SATA HDD/SSD and has RAID 0, 1, 5 and 6 Support. If supercapacitor needs to be replaced, it can be done so by ordering UCSB-MRAID-SC=. See Installation Document for instructions

The flash-backed write cache provides RAID controller cache protection using NAND flash memory and a supercapacitor. In the event of a power or server failure, cached data is automatically transferred from the RAID controller DRAM write cache to flash. Once power is restored, the data in the NAND flash is copied back into the DRAM write cache until it can be flushed to the disk drives. 5. For NVMe, the Cisco FlexStorage NVMe Passthrough module is required.

26 Cisco UCS B200 M5 Blade Server UCS B200 Ready2Ship Program

6. For servers that do not need local storage, and where no storage controllers are included, storage blanking panels are auto-included as a part of the ordering configuration rules. In order for the UCS B200 M5 to function properly and not overheat, drive blanks must be installed if no storage controller or GPU is used. 7. For GPU P6, maximum cards per node supported is two

Cisco UCS B200 M5 Blade Server 27 UCS B200 Ready2Ship Program

STEP 8 CHOOSE OPTIONAL DRIVES

The UCS B200 M5 can be ordered with or without drives. The standard drive features are:

■ 2.5-inch small form factor ■ Hot-pluggable ■ Sled-mounted ■ The B200 M5 supports hard disk drives (HDD), Solid State Drives (SSD) or Non-Volatile Memory Express (NVMe) Drives ■ One or two drives can be selected ■ Drives always require one storage controller listed in Table 16 Available Front Mezzanine Adapters, page 26.

Select one or two drives from the list of supported drives available in Table 16.

Available Drive Options

Performance/ Drive Product ID (PID) Description Speed Endurance Size Type /Value

HDD1

UCS-HD900G15K12G 900 GB 12G SAS 15K RPM SFF HDD SAS 15K RPM N/A 900 GB

UCS-HD600G15K12G 600 GB 12G SAS 15K RPM SFF HDD SAS 15K RPM N/A 600 GB

UCS-HD300G15K12G 300 GB 12G SAS 15K RPM SFF HDD SAS 15K RPM N/A 300 GB

UCS-HD24TB10KS4K 2.4 TB 12G SAS 10K RPM SFF HDD (4K)2 SAS 10K RPM N/A 2400 GB

UCS-HD18TB10KS4K 1.8 TB 12G SAS 10K RPM SFF HDD (4K)2 SAS 10K RPM N/A 1800 GB

UCS-HD12TB10K12G 1.2 TB 12G SAS 10K RPM SFF HDD SAS 10K RPM N/A 1200 GB

UCS-HD600G10K12G 600 GB 12G SAS 10K RPM SFF HDD SAS 10K RPM N/A 600 GB

UCS-HD300G10K12G 300 GB 12G SAS 10K RPM SFF HDD SAS 10K RPM N/A 300 GB

SSD1

Enterprise Performance (high endurance, supports up to 10X or 3X DWPD (drive writes per day))

UCS-SD800GSAS3-EP 800 GB 2.5 inch Enterprise SAS 12G Ent. Perf 3X 800 GB performance 12G SAS SSD(3X endurance) (Toshiba PX05)

UCS-SD16TH3-EP 1.6 TB 2.5 inch Enterprise performance SAS 12G Ent. Perf 3X 1600 GB 12G SAS SSD (3X DWPD)

UCS-SD32TH3-EP 3.2 TB 2.5in Enterprise performance SAS 12G Ent. Perf 3X 3200 GB 12G SAS SSD (3X DWPD)

28 Cisco UCS B200 M5 Blade Server UCS B200 Ready2Ship Program

Available Drive Options (continued)

Performance/ Drive Product ID (PID) Description Speed Endurance Size Type /Value

UCS-SD800GKB3X-EP 800GB 2.5in Enterprise Performance SAS 12G Ent. Perf 3X 800 GB 12G SAS SSD(3X endurance)

UCS-SD16TKB3X-EP 1.6TB 2.5in Enterprise Performance SAS 12G Ent. Perf 3X 1600 GB 12G SAS SSD(3X endurance)

UCS-SD32TKB3X-EP 3.2TB 2.5in Enterprise Performance SAS 12G Ent. Perf 3X 3200 GB 12G SAS SSD(3X endurance)

UCS-SD480GIS3-EP 480 GB 2.5in Enterprise performance SATA 6G Ent. Perf 3X 480 GB 6G SATA SSD(3X endurance)

UCS-SD960GIS3-EP 960 GB 2.5in Enterprise performance SATA 6G Ent. Perf 3X 960 GB 6G SATA SSD(3X endurance

UCS-SD19TIS3-EP 1.9 TB 2.5in Enterprise performance 6G SATA 6G Ent. Perf 3X 1900 GB SATA SSD(3X endurance)

UCS-SD480GMB3X-EP 480 GB 2.5in Enterprise performance SATA 6G Ent. Perf 3X 480 GB 6G SATA SSD(3X endurance)

UCS-SD960GMB3X-EP 960 GB 2.5in Enterprise performance SATA 6G Ent. Perf 3X 960 GB 6GSATA SSD(3X endurance)

UCS-SD19TMB3X-EP 1.9 TB 2.5in Enterprise performance SATA 6G Ent. Perf 3X 1900 GB 6GSATA SSD(3X endurance)

Enterprise Value SSDs (Low endurance, supports up to 1X DWPD (drive writes per day))

UCS-SD960GKB1X-EV 960GB 2.5 inch Enterprise Value 12G SAS 12G Ent. Value 960 GB SAS SSD

UCS-SD19TKB1X-EV 1.9TB 2.5 inch Enterprise Value 12G SAS SAS 12G Ent. Value 1900 GB SSD

UCS-SD38TKB1X-EV 3.8TB 2.5 inch Enterprise Value 12G SAS SAS 12G Ent. Value 3800 GB SSD

UCS-SD76TKB1X-EV 7.6TB 2.5 inch Enterprise Value 12G SAS SAS 12G Ent. Value 7600 GB SSD

UCS-SD15TKB1X-EV 15.3TB 2.5 inch Enterprise Value 12G SAS 12G Ent. Value 15300 SAS SSD GB

UCS-SD960GBKS4-EV 960 GB 2.5 inch Enterprise Value 6G SATA 6G Ent. Value 960 GB SATA SSD (Samsung PM863A/PM883)

UCS-SD38TBKS4-EV 3.8 TB 2.5 inch Enterprise Value 6G SATA 6G Ent. Value 3800 GB SATA SSD (Samsung PM863A/PM883)

UCS-SD120GBMS4-EV 120 GB 2.5 inch Enterprise Value 6G SATA 6G Ent. Value 120 GB SATA SSD (Micron 5100/5200)

Cisco UCS B200 M5 Blade Server 29 UCS B200 Ready2Ship Program

Available Drive Options (continued)

Performance/ Drive Product ID (PID) Description Speed Endurance Size Type /Value

UCS-SD240GBMS4-EV 240 GB 2.5 inch Enterprise Value 6G SATA 6G Ent. Value 240 GB SATA SSD (Micron 5100/5200)

UCS-SD480GBMS4-EV 480 GB 2.5 inch Enterprise Value 6G SATA 6G Ent. Value 480 GB SATA SSD (Micron 5100/5200)

UCS-SD960GBMS4-EV 960 GB 2.5 inch Enterprise Value 6G SATA 6G Ent. Value 960 GB SATA SSD (Micron 5100/5200)

UCS-SD16TBMS4-EV 1.6 TB 2.5 inch Enterprise Value 6G SATA 6G Ent. Value 1600 GB SATA SSD (Micron 5100/5200)

UCS-SD19TBMS4-EV 1.9 TB 2.5 inch Enterprise Value 6G SATA 6G Ent. Value 1900 GB SATA SSD (Micron 5100/5200)

UCS-SD38TBMS4-EV 3.8 TB 2.5 inch Enterprise Value 6G SATA 6G Ent. Value 3800 GB SATA SSD (Micron 5100/5200)

UCS-SD76TSB61X-EV 7.6 TB 2.5 inch Enterprise Value 6G SATA 6G Ent. Value 7600 GB SATA SSD

UCS-SD76TBMS4-EV 7.6 TB 2.5 inch Enterprise Value 6G SATA 6G Ent. Value 7600 GB SATA SSD (Micron 5100/5200)

UCS-SD480GBIS6-EV 480 GB 2.5 inch Enterprise Value 6G SATA 6G Ent. Value 480 GB SATA SSD (Intel S4500/S4150)

UCS-SD960GBIS6-EV 960 GB 2.5 inch Enterprise Value 6G SATA 6G Ent. Value 960 GB SATA SSD (Intel S4500/S4150)

UCS-SD38TBIS6-EV 3.8 TB 2.5 inch Enterprise Value 6G SATA 6G Ent. Value 3800 GB SATA SSD (Intel S4500/S4150)

Self-Encrypted Drives (SEDs)

UCS-HD600G15K9 600 GB 12G SAS 15K RPM SFF HDD SAS 15K RPM N/A 600 GB (SED)FIPS 140-2

UCS-HD18G10K9 1.8 TB 12G SAS 10K RPM SFF HDD (4K SAS 10K RPM N/A 1800 GB format, SED)FIPS 140-2

UCS-HD24T10BNK9 2.4 TB 12G SAS 10K RPM SFF HDD (4K SAS 10K RPM N/A 2400 GB format, SED)FIPS 140-2

UCS-SD800GBKNK9 800GB Enterprise Performance SAS SSD SAS Ent. Perf 3X 800 GB (3X FWPD, SED)

UCS-SD960GBKNK9 960GB Enterprise Value SAS SSD (1X SAS Ent. Value 1X 960 GB FWPD, SED)

UCS-SD38TBKNK9 3.8TB Enterprise Value SAS SSD (1X SAS Ent. Value 1X 3.8 TB FWPD, SED)

30 Cisco UCS B200 M5 Blade Server UCS B200 Ready2Ship Program

Available Drive Options (continued)

Performance/ Drive Product ID (PID) Description Speed Endurance Size Type /Value

UCS-SD16TBKNK9 1.6TB Enterprise performance SAS SSD SAS Ent. Perf 3X 1.6 TB (3X FWPD, SED)

NVMe3,4,5

UCSB-NVMEHW-H800 Cisco 2.5" U.2 800 GB HGST SN200 NVMe High High 800 GB NVMe High Perf. High Endurance Perf Perf/High Endurance

UCSB-NVMEHW-H6400 Cisco 2.5" U.2 6.4 TB HGST SN200 NVMe NVMe High High 6400 GB High Perf. High Endurance Perf Perf/High Endurance

UCSB-NVMEHW-H7680 Cisco 2.5" U.2 7.7 TB HGST SN200 NVMe NVMe High High 7680 GB High Perf. Value Endurance Perf Perf/Value Endurance

UCSB-NVMEHW-I8000 Cisco 2.5" U.2 8TB Intel P4510 NVMe NVMe High High 8000 GB High Perf. Value Endurance Perf Perf/Value Endurance

UCSB-NVMEXPB-I375 Cisco 2.5in U.2 375GB Intel P4800 NVMe NVMe Med Med Perf 375 GB Med. Perf Perf

UCSB-NVMEXP-I750 750 GB 2.5in Intel Optane NVMe NVMe Extrm Extreme Perf 750 GB Extreme Perf Perf

UCSB-NVME2H-I1000 Cisco 2.5" U.2 1,0 TB Intel P4510 NVMe NVMe High High 1000 GB High Perf. Value Endurance Perf Perf/Value Endurance

UCSB-NVME2H-I1600 Cisco 2.5" U.2 1.6TB Intel P4610 NVMe NVMe High High 1600 GB High Perf. High Endurance Perf Perf/High Endurance

UCSB-NVME2H-I2TBV Cisco 2.5" U.2 2.0TB Intel P4510 NVMe NVMe High High 2000 GB High Perf. Value Endurance Perf Perf/Value Endurance

UCSB-NVME2H-I3200 Cisco 2.5" U.2 3.2TB Intel P4610 NVMe NVMe High High 3200 GB High Perf. High Endurance Perf Perf/High Endurance

UCSB-NVME2H-I4000 Cisco 2.5" U.2 4.0TB Intel P4510 NVMe NVMe High High 4000 GB High Perf. Value Endu Perf Perf/Value Endurance

UCSB-NVMHG-W1600 1.6TB 2.5in U.2 WD SN840 NVMe NVMe Extrm Extrm 1.6 TB Extreme Perf. High Endurance Perf Perf/High Endurance

Cisco UCS B200 M5 Blade Server 31 UCS B200 Ready2Ship Program

Available Drive Options (continued)

Performance/ Drive Product ID (PID) Description Speed Endurance Size Type /Value

UCSB-NVMHG-W3200 3.2TB 2.5in U.2 WD SN840 NVMe NVMe Extrm Extrm 3.2 TB Extreme Perf. High Endurance Perf Perf/High Endurance

UCSB-NVMHG-W6400 6.4TB 2.5in U.2 WD SN840 NVMe NVMe Extrm Extrm 6.4 TB Extreme Perf. High Endurance Perf Perf/High Endurance

UCSB-NVMHG-W7600 7.6TB 2.5in U.2 WD SN840 NVMe NVMe Extrm Extrm 7.6 TB Extreme Perf. Value Endurance Perf Perf/High Endurance

UCSB-NVMHG-W15300 15.3TB 2.5in U.2 WD SN840 NVMe NVMe Extrm Extrm 15.3 TB Extreme Perf. High Endurance Perf Perf/High Endurance

Notes: 1. HDDs and SSDs require either of the following storage controllers in the front mezzanine slot: UCSB-MRAID12G, or UCSB-MRAID12G-HE 2. For 4K native (4Kn) drives: VMWare ESXi 6.0 does not support 4Kn Drives. 4Kn drive support with VMWare is available in release 6.7 and later. 4K native drives require UEFI Boot 3. NVMe drives require the following storage controller in the front mezzanine slot: UCSB-LSTOR-PT 4. For HDD or SSD drives to be in a RAID group, two identical HDDs or SSDs must be used in the group. 5. If HDD or SSD are in JBOD Mode, the drives do not need to be identical.

NOTE: Cisco uses solid state drives (SSDs) from a number of vendors. All solid state drives (SSDs) are subject to physical write limits and have varying maximum usage limitation specifications set by the manufacturer. Cisco will not replace any solid state drives (SSDs) that have exceeded any maximum usage specifications set by Cisco or the manufacturer, as determined solely by Cisco.

32 Cisco UCS B200 M5 Blade Server UCS B200 Ready2Ship Program

STEP 9 CHOOSE OPTIONAL SECURE DIGITAL CARDS or M.2 DRIVES

A mini-storage connector is provided on the motherboard. There are two choices of mini-storage modular adapters that fit in the connector on the motherboard.

1. Adapter with two SD HC sockets that accommodate up to two SDHC cards 2. Adapter with two M.2 sockets that accommodate up to two M.2 devices

SD Cards and Modular Adapter The SDHC card ordering information is listed in Table 17.

Table 17 PIDs for Secure Digital High-Capacity Card(s) and Modular Adapter

Product ID (PID) PID Description

UCS-SD-32G-S 32 GB SD Card for UCS servers

UCS-SD-64G-S 64 GB SD Card for UCS servers

UCS-SD-128G 128GB SD Card for UCS servers

UCS-MSTOR-SD1 Modular adapter for SD card

Notes: 1. The SD modular adapter (PID UCS-MSTOR-SD) is auto-included in CCW and is not selectable.

Supported Configurations

(1) Select one or two Cisco secure digital cards

■ Select up to two 32, 64, or 128 GB SD cards

(2) Do not mix SD cards

(3) If you select SDHC cards, you cannot select any M.2 SATA SSD drive.

M.2 SATA Cards and Modular Adapter Order one or two matching M.2 SATA SSDs (see Table 18) along with a mini storage carrier or a boot-optimized RAID controller (see Table 19).

NOTE: It is recommended that M.2 SATA SSDs be used as boot-only devices.

Cisco UCS B200 M5 Blade Server 33 UCS B200 Ready2Ship Program

Each mini storage carrier or boot-optimized RAID controller can accommodate up to two SATA M.2 SSDs shown in Table 18.

Table 18 M.2 SATA SSDs

Product ID (PID) PID Description

UCS-M2-240GB 240 GB M.2 SATA SSD

UCS-M2-960GB 960 GB M.2 SATA SSD

Table 19 Mini Storage Carrier/Boot-Optimized RAID Controller

Product ID (PID) PID Description

UCS-MSTOR-M2 Mini Storage Carrier for M.2 SATA (holds up to 2 M.2 SATA SSDs)

UCS-M2-HWRAID Cisco Boot optimized M.2 RAID controller (holds up to 2 M.2 SATA SSDs)

NOTE: ■ The UCS-M2-HWRAID boot-optimized RAID controller supports RAID 1 and JBOD mode ■ The UCS-M2-HWRAID controller is available only with 240 GB and 960 GB M.2 SSDs. ■ (CIMC/UCSM) is supported for configuring of volumes and monitoring of the controller and installed SATA M.2 drives ■ The minimum version of Cisco IMC and Cisco UCS Manager that support this controller is 4.0(4) and later. The name of the controller in the software is MSTOR-RAID ■ The SATA M.2 drives can boot in UEFI mode only. Legacy boot mode is not supported ■ Hot-plug replacement is not supported. The server must be powered off. ■ The boot-optimized RAID controller is not supported when the server is used as a compute node in HyperFlex configurations

■ Order either the Mini Storage carrier or the Boot-Optimized RAID controller from Table 19. — Choose the UCS-MSTOR-M2 mini storage carrier for controlling the M.2 SATA drives with no RAID control. — Choose the UCS-M2-HWRAID Boot-Optimized RAID controller for hardware RAID across the two internal SATA M.2 drives. The Boot-Optimized RAID controller holds up to 2 matching M.2 SATA drives. ■ Order up to two matching M.2 SATA SSDs from Table 18.

NOTE: The Boot-Optimized RAID controller supports VMWare, Windows and Linux Operating Systems

34 Cisco UCS B200 M5 Blade Server UCS B200 Ready2Ship Program

Caveats

■ You cannot mix M.2 SATA SSDs with SD cards. ■ Order either one or two identical M.2 SATA SSDs for the mini-storage carrier or boot-optimized RAID controller. You cannot mix M.2 SATA SSD capacities.

When ordering two M.2 SATA drives with embedded software RAID, the maximum number of internal SATA drives supported is six. To support greater than six internal drives, a Cisco 12G Raid Controller or a Cisco 12G SAS HBA must be ordered

Cisco UCS B200 M5 Blade Server 35 UCS B200 Ready2Ship Program

STEP 10 CHOOSE OPTIONAL TRUSTED PLATFORM MODULE

Trusted Platform Module (TPM) is a computer chip or microcontroller that can securely store artifacts used to authenticate the platform or server. These artifacts can include passwords, certificates, or encryption keys. A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy. Authentication (ensuring that the platform can prove that it is what it claims to be) and attestation (a process helping to prove that a platform is trustworthy and has not been breached) are necessary steps to ensure safer computing in all environments.

Table 20 Available TPM Option

Product ID (PID) Description

UCSX-TPM2-001 Trusted Platform Module 1.2 for UCS (SPI-based)

UCSX-TPM2-002 Trusted Platform Module 2.0 for UCS servers

UCSX-TPM2-002B Trusted Platform Module2.0 M5 UCS svr (FIPS 140-2 Compliant)

NOTE:

1. The TPM module used in this system conforms to TPM v1.2 and 2.0, as defined by the Trusted Computing Group (TCG). It is also SPI-based.

■ 2. TPM installation is supported after-factory. However, a TPM installs with a one-way screw and cannot be replaced, upgraded, or moved to another server. If a server with a TPM is returned, the replacement server must be ordered with a new TPM. If there is no existing TPM in the server, you can install TPM 2.0. Refer to the following document for Installation location and instructions: Cisco UCS B200 M5 Server Installation Guide.

36 Cisco UCS B200 M5 Blade Server UCS B200 Ready2Ship Program

STEP 11 CHOOSE OPTIONAL INTERNAL USB 3.0 DRIVE

You may order one optional internal USB 3.0 drive. The USB drive ordering information is listed in Table 21.

Table 21 Available USB Option

Product ID (PID) Description

UCS-USBFLSHB-16GB UCS Servers 16GB Flash USB Drive

NOTE: A clearance of 0.950 inches (24.1 mm) is required for the USB device to be inserted and removed (see Figure 4). The USB drive listed in Table 21 has the correct clearance. If you choose your own USB drive, it must have the required clearance.

Figure 4 USB Clearance

Cisco UCS B200 M5 Blade Server 37 UCS B200 Ready2Ship Program

STEP 12 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARE

For more details on supported operating systems and software for this server, see the Hardware and Software Compatibility List (HCL

Select

■ Cisco Software (Table 22) ■ OEM Software (Table 23) ■ Operating System (Table 24)

Table 22 Cisco Software

Product ID (PID) PID Description

Nexus 1000V for Hyper-V and vSphere

N1K-VSG-UCS-BUN Nexus 1000V Adv Edition for vSphere Paper License Qty 1

UCS Multi-Domain Manager

UCS-MDMGR-1S UCS Central Per Server License

NOTE: IF you must order quantity greater than 1 of UCS-MDMGR-1S, you need to reference the UCS Central Per Server Data Sheet to order the standalone PIDs: UCS-MDMGR-LIC= or UCS-MDMGR-1DMN=

Table 23 OEM Software

Product ID (PID) PID Description

VMware vCenter

VMW-VCS-STD-1A VMware vCenter 6 Server Standard, 1 yr support required

VMW-VCS-STD-3A VMware vCenter 6 Server Standard, 3 yr support required

VMW-VCS-STD-5A VMware vCenter 6 Server Standard, 5 yr support required

VMW-VCS-FND-1A VMware vCenter 6 Server Foundation (4 Host), 1 yr supp reqd

VMW-VCS-FND-3A VMware vCenter 6 Server Foundation (4 Host), 3 yr supp reqd

VMW-VCS-FND-5A VMware vCenter 6 Server Foundation (4 Host), 5 yr supp reqd

38 Cisco UCS B200 M5 Blade Server UCS B200 Ready2Ship Program

Table 24 Operating System

Product ID (PID) PID Description

Microsoft Windows Server

MSWS-19-DC16C Windows Server 2019 Data Center (16 Cores/Unlimited VMs)

MSWS-19-DC16C-NS Windows Server 2019 DC (16 Cores/Unlim VMs) - No Cisco SVC

MSWS-19-ST16C Windows Server 2019 Standard (16 Cores/2 VMs)

MSWS-19-ST16C-NS Windows Server 2019 Standard (16 Cores/2 VMs) - No Cisco SVC

Red Hat

RHEL-2S2V-1A Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 1-Yr Support Req

RHEL-2S2V-3A Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 3-Yr Support Req

RHEL-2S2V-5A Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 5-Yr Support Req

RHEL-VDC-2SUV-1A RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 1 Yr Supp Req

RHEL-VDC-2SUV-3A RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 3 Yr Supp Req

RHEL-VDC-2SUV-5A RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 5 Yr Supp Req

Red Hat Ent Linux/ High Avail/ Res Strg/ Scal

RHEL-2S2V-1S Red Hat Enterprise Linux (1-2 CPU,1-2 VN); Prem 1-Yr SnS

RHEL-2S2V-3S Red Hat Enterprise Linux (1-2 CPU,1-2 VN); Prem 3-Yr SnS

RHEL-2S-HA-1S RHEL High Availability (1-2 CPU); Premium 1-yr SnS

RHEL-2S-HA-3S RHEL High Availability (1-2 CPU); Premium 3-yr SnS

RHEL-2S-RS-1S RHEL Resilent Storage (1-2 CPU); Premium 1-yr SnS

RHEL-2S-RS-3S RHEL Resilent Storage (1-2 CPU); Premium 3-yr SnS

RHEL-2S-SFS-1S RHEL Scalable File System (1-2 CPU); Premium 1-yr SnS

RHEL-2S-SFS-3S RHEL Scalable File System (1-2 CPU); Premium 3-yr SnS

RHEL-VDC-2SUV-1S RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 1 Yr SnS Reqd

RHEL-VDC-2SUV-3S RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 3 Yr SnS Reqd

Red Hat SAP

RHEL-SAP-2S2V-1S RHEL for SAP Apps (1-2 CPU, 1-2 VN); Prem 1-Yr SnS Reqd

RHEL-SAP-2S2V-3S RHEL for SAP Apps (1-2 CPU, 1-2 VN); Prem 3-Yr SnS Reqd

RHEL-SAPSP-3S RHEL SAP Solutions Premium - License with 3 Years of SnS

RHEL-SAPSS-3S RHEL SAP Solutions Standard - License with 3 Years of SnS

Cisco UCS B200 M5 Blade Server 39 UCS B200 Ready2Ship Program

Table 24 (continued)Operating System

Product ID (PID) PID Description

VMware

VMW-VSP-STD-1A VMware vSphere 6 Standard (1 CPU), 1-yr, Support Required

VMW-VSP-STD-3A VMware vSphere 6 Standard (1 CPU), 3-yr, Support Required

VMW-VSP-STD-5A VMware vSphere 6 Standard (1 CPU), 5-yr, Support Required

VMW-VSP-EPL-3A VMware vSphere 6 Ent Plus (1 CPU), 3-yr, Support Required

VMW-VSP-EPL-1A VMware vSphere 6 Ent Plus (1 CPU), 1-yr, Support Required

VMW-VSP-EPL-5A VMware vSphere 6 Ent Plus (1 CPU), 5-yr, Support Required

SUSE

SLES-2S2V-1A SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 1-Yr Support Req

SLES-2SUV-1A SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); 1-Yr Support Req

SLES-2S2V-3A SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 3-Yr Support Req

SLES-2SUV-3A SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); 3-Yr Support Req

SLES-2S2V-5A SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 5-Yr Support Req

SLES-2SUV-5A SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); 5-Yr Support Req

SLES-2S2V-1S SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 1-Yr SnS

SLES-2SUV-1S SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); Prio 1-Yr SnS

SLES-2S2V-3S SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 3-Yr SnS

SLES-2SUV-3S SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); Prio 3-Yr SnS

SLES-2S2V-5S SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 5-Yr SnS

SLES-2SUV-5S SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); Prio 5-Yr SnS

SLES-2S-HA-1S SUSE Linux High Availability Ext (1-2 CPU); 1yr SnS

SLES-2S-HA-3S SUSE Linux High Availability Ext (1-2 CPU); 3yr SnS

SLES-2S-HA-5S SUSE Linux High Availability Ext (1-2 CPU); 5yr SnS

SLES-2S-GC-1S SUSE Linux GEO Clustering for HA (1-2 CPU); 1yr Sns

SLES-2S-GC-3S SUSE Linux GEO Clustering for HA (1-2 CPU); 3yr SnS

SLES-2S-GC-5S SUSE Linux GEO Clustering for HA (1-2 CPU); 5yr SnS

SLES-2S-LP-1S SUSE Linux Live Patching Add-on (1-2 CPU); 1yr SnS Required

SLES-2S-LP-3S SUSE Linux Live Patching Add-on (1-2 CPU); 3yr SnS Required

40 Cisco UCS B200 M5 Blade Server UCS B200 Ready2Ship Program

Table 24 (continued)Operating System

Product ID (PID) PID Description

SLES-2S-LP-1A SUSE Linux Live Patching Add-on (1-2 CPU); 1yr Support Req

SLES-2S-LP-3A SUSE Linux Live Patching Add-on (1-2 CPU); 3yr Support Req

SLES and SAP

SLES-SAP-2S2V-1A SLES for SAP Apps (1-2 CPU, 1-2 VM); 1-Yr Support Reqd

SLES-SAP-2SUV-1A SLES for SAP Apps (1-2 CPU, Unl VM); 1-Yr Support Reqd

SLES-SAP-2S2V-3A SLES for SAP Apps (1-2 CPU, 1-2 VM); 3-Yr Support Reqd

SLES-SAP-2SUV-3A SLES for SAP Apps (1-2 CPU, Unl VM); 3-Yr Support Reqd

SLES-SAP-2S2V-5A SLES for SAP Apps (1-2 CPU, 1-2 VM); 5-Yr Support Reqd

SLES-SAP-2SUV-5A SLES for SAP Apps (1-2 CPU, Unl VM); 5-Yr Support Reqd

SLES-SAP-2S2V-1S SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 1-Yr SnS

SLES-SAP-2SUV-1S SLES for SAP Apps (1-2 CPU, Unl VM); Priority 1-Yr SnS

SLES-SAP-2S2V-3S SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 3-Yr SnS

SLES-SAP-2SUV-3S SLES for SAP Apps (1-2 CPU, Unl VM); Priority 3-Yr SnS

SLES-SAP-2S2V-5S SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 5-Yr SnS

SLES-SAP-2SUV-5S SLES for SAP Apps (1-2 CPU, Unl VM); Priority 5-Yr SnS

Cisco UCS B200 M5 Blade Server 41 UCS B200 Ready2Ship Program

STEP 13 CHOOSE OPTIONAL OPERATING SYSTEM MEDIA KIT

Select the optional operating system media listed in Table 25

Table 25 OS Media

Product ID (PID) PID Description

MSWS-19-ST16C-RM Windows Server 2019 Stan (16 Cores/2 VMs) Rec Media DVD Only

MSWS-19-DC16C-RM Windows Server 2019 DC (16Cores/Unlim VM) Rec Media DVD Only

42 Cisco UCS B200 M5 Blade Server UCS B200 Ready2Ship Program

STEP 14 CHOOSE SERVICE and SUPPORT LEVEL

A variety of service options are available, as described in this section.

Unified Computing Warranty, No Contract

If you have noncritical implementations and choose to have no service contract, the following coverage is supplied:

• Three-year parts coverage. • Next business day (NBD) parts replacement eight hours a day, five days a week. • 90-day software warranty on media. • Downloads of BIOS, drivers, and firmware updates. • UCSM updates for systems with Unified Computing System Manager. These updates include minor enhancements and bug fixes that are designed to maintain the compliance of UCSM with published specifications, release notes, and industry standards.

Unified Computing Support Service For support of the entire Unified Computing System, Cisco offers the Cisco Smart Net Total Care for UCS Service. This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment. Access to Cisco Technical Assistance Center (TAC) is provided around the clock, from anywhere in the world

For systems that include Unified Computing System Manager, the support service includes downloads of UCSM upgrades. The Cisco Smart Net Total Care for UCS Service includes flexible hardware replacement options, including replacement in as little as two hours. There is also access to Cisco's extensive online technical resources to help maintain optimal efficiency and uptime of the unified computing environment. For more information please refer to the following url: http://www.cisco.com/c/en/us/services/technical/smart-net-total-care.html?stickynav=1You can choose a desired service listed in Table 26.

Table 26 Unified Computing Support Service

Service SKU Service Level GSP On Site? Description

CON-PREM-SBB200M5 C2P Yes SNTC 24X7X2OS

CON-UCSD8-SBB200M5 UCSD8 Yes UC SUPP DR 24X7X2OS*

CON-C2PL-SBB200M5 C2PL Yes LL 24X7X2OS**

CON-OSP-SBB200M5 C4P Yes SNTC 24X7X4OS

CON-UCSD7-SBB200M5 UCSD7 Yes UCS DR 24X7X4OS*

CON-C4PL-SBB200M5 C4PL Yes LL 24X7X4OS**

CON-USD7L-SBB200M5 USD7L Yes LLUCS HW DR 24X7X4OS***

CON-OSE-SBB200M5 C4S Yes SNTC 8X5X4OS

Cisco UCS B200 M5 Blade Server 43 UCS B200 Ready2Ship Program

Table 26 Unified Computing Support Service (continued)

Service SKU Service Level GSP On Site? Description

CON-UCSD6-SBB200M5 UCSD6 Yes UC SUPP DR 8X5X4OS*

CON-SNCO-SBB200M5 SNCO Yes SNTC 8x7xNCDOS****

CON-OS-SBB200M5 CS Yes SNTC 8X5XNBDOS

CON-UCSD5-SBB200M5 UCSD5 Yes UCS DR 8X5XNBDOS*

CON-S2P-SBB200M5 S2P No SNTC 24X7X2

CON-S2PL-SBB200M5 S2PL No LL 24X7X2**

CON-SNTP-SBB200M5 SNTP No SNTC 24X7X4

CON-SNTPL-SBB200M5 SNTPL No LL 24X7X4**

CON-SNTE-SBB200M5 SNTE No SNTC 8X5X4

CON-SNC-SBB200M5 SNC No SNTC 8x7xNCD****

CON-SNT-SBB200M5 SNT No SNTC 8X5XNBD

CON-SW-SBB200M5 SW No SNTC NO RMA

Note: For PID UCSB-B200-M5-U, select Service SKU with BB200M5U suffix (Example: CON-PREM- BB200M5U)

For PID UCSB-B200-M5-CH, select Service SKU with B200M5CH suffix (Example: CON-PREM- B200M5CH)

*Includes Drive Retention (see UCS Drive Retention Service on page 48)

**Includes Local Language Support (see Local Language Technical Support for UCS on page 49) – Only available in China and Japan

***Includes Local Language Support and Drive Retention – Only available in China and Japan

****Available in China Only

Smart Net Total Care for Cisco UCS Onsite Troubleshooting Service For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty, Cisco offers the Cisco Smart Net Total Care for UCS Hardware Only Service. You can choose from two levels of advanced onsite parts replacement coverage in as little as four hours. Smart Net Total Care for UCS Hardware Only Service provides remote access any time to Cisco support professionals who can determine if a return materials authorization (RMA) is required. You can choose a desired service listed in Table 27.

Table 27 SNTC for Cisco UCS Onsite Troubleshooting Service (PID UCSB-B200-M5)

Service SKU Service Level GSP On Site? Description

CON-UCW7-SBB200M5 UCW7 Yes UCS HW 24X7X4OS CON-UCWD7-SBB200M5 UCWD7 Yes UCS HW+DR 24X7X4OS*

44 Cisco UCS B200 M5 Blade Server UCS B200 Ready2Ship Program

Table 27 SNTC for Cisco UCS Onsite Troubleshooting Service (PID UCSB-B200-M5) (continued)

Service SKU Service Level GSP On Site? Description

CON-UCW7L-SBB200M5 UCW7L Yes LL UCS 24X7X4OS**

CON-UWD7L-SBB200M5 UWD7L Yes LL UCS DR 24X7X4OS***

CON-UCW5-SBB200M5 UCW5 Yes UCS HW 8X5XNBDOS

CON-UCWD5-SBB200M5 UCWD5 Yes UCS HW+DR 8X5XNBDOS*

Note: For PID UCSB-B200-M5-U, select Service SKU with BB200M5U suffix (Example: CON-PREM- BB200M5U)

For PID UCSB-B200-M5-CH, select Service SKU with B200M5CH suffix (Example: CON-PREM- B200M5CH)

*Includes Drive Retention (see UCS Drive Retention Service on page 48)

**Includes Local Language Support (see Local Language Technical Support for UCS on page 49) – Only available in China and Japan

***Includes Local Language Support and Drive Retention – Only available in China and Japan

Partner Support Service for UCS Cisco Partner Support Service (PSS) is a Cisco Collaborative Services service offering that is designed for partners to deliver their own branded support and managed services to enterprise customers. Cisco PSS provides partners with access to Cisco's support infrastructure and assets to help them:

■ Expand their service portfolios to support the most complex network environments ■ Lower delivery costs ■ Deliver services that increase customer loyalty

PSS options enable eligible Cisco partners to develop and consistently deliver high-value technical support that capitalizes on Cisco intellectual assets. This helps partners to realize higher margins and expand their practice.

PSS is available to all Cisco PSS partners.

The two Partner Unified Computing Support Options include:

■ Partner Support Service for UCS ■ Partner Support Service for UCS Hardware Only

PSS for UCS provides hardware and software support, including triage support for third party software, backed by Cisco technical resources and level three support. You can choose a desired service listed in Tabl e 28.

Table 28 PSS for UCS (PID UCSB-B200-M5)

Service SKU Service Level GSP On Site? Description

CON-PSJ8-SBB200M5 PSJ8 Yes UCS PSS 24X7X2 OS CON-PSJ7-SBB200M5 PSJ7 Yes UCS PSS 24X7X4 OS

Cisco UCS B200 M5 Blade Server 45 UCS B200 Ready2Ship Program

Table 28 PSS for UCS (PID UCSB-B200-M5) (continued)

Service SKU Service Level GSP On Site? Description

CON-PSJD7-SBB200M5 PSJD7 Yes UCS PSS 24X7X4 DR* CON-PSJ6-SBB200M5 PSJ6 Yes UCS PSS 8X5X4 OS CON-PSJD6-SBB200M5 PSJD6 Yes UCS PSS 8X5X4 DR* CON-PSJ4-SBB200M5 PSJ4 No UCS SUPP PSS 24X7X2 CON-PSJ3-SBB200M5 PSJ3 No UCS SUPP PSS 24X7X4

CON-PSJ2-SBB200M5 PSJ2 No UCS SUPP PSS 8X5X4

CON-PSJ1-SBB200M5 PSJ1 No UCS SUPP PSS 8X5XNBD

Note: For PID UCSB-B200-M5-U, select Service SKU with BB200M5U suffix (Example: CON-PREM- BB200M5U)

For PID UCSB-B200-M5-CH, select Service SKU with B200M5CH suffix (Example: CON-PREM- B200M5CH)

*Includes Drive Retention (see UCS Drive Retention Service on page 48)

PSS for UCS Hardware Only PSS for UCS Hardware Only provides customers with replacement parts in as little as two hours and provides remote access any time to Partner Support professionals who can determine if a return materials authorization (RMA) is required. You can choose a desired service listed in Table 29 Table 29 PSS for UCS Hardware Only (PID UCSB-B200-M5)

Service SKU Service Level GSP On Site? Description

CON-PSW7-SBB200M5 PSW7 Yes UCS W PSS 24X7X4 OS

CON-PSWD7-SBB200M5 PSWD7 Yes UCS W PSS 24X7X4 DR*

CON-PSW6-SBB200M5 PSW6 Yes UCS W PSS 8X5X4 OS

CON-PSWD6-SBB200M5 PSWD6 Yes UCS W PSS 8X5X4 DR*

CON-PSW4-SBB200M5 PSW4 No UCS W PL PSS 24X7X2

CON-PSW3-SBB200M5 PSW3 No UCS W PL PSS 24X7X4

CON-PSW2-SBB200M5 PSW2 No UCS W PL PSS 8X5X4

Note: For PID UCSB-B200-M5-U, select Service SKU with BB200M5U suffix (Example: CON-PREM- BB200M5U)

For PID UCSB-B200-M5-CH, select Service SKU with B200M5CH suffix (Example: CON-PREM- B200M5CH)

*Includes Drive Retention (see UCS Drive Retention Service on page 48)

46 Cisco UCS B200 M5 Blade Server UCS B200 Ready2Ship Program

Unified Computing Combined Support Service Combined Services makes it easier to purchase and manage required services under one contract. SNTC services for UCS help increase the availability of your vital data center infrastructure and realize the most value from your unified computing investment. The more benefits you realize from the Cisco Unified Computing System (Cisco UCS), the more important the technology becomes to your business. These services allow you to:

■ Optimize the uptime, performance, and efficiency of your UCS ■ Protect your vital business applications by rapidly identifying and addressing issues ■ Strengthen in-house expertise through knowledge transfer and mentoring ■ Improve operational efficiency by allowing UCS experts to augment your internal staff resources ■ Enhance business agility by diagnosing potential issues before they affect your operations You can choose a desired service listed inTable 30.

Table 30 Combined Support Service for UCS (PID UCSB-B200-M5)

Service SKU Service Level GSP On Site? Description

CON-NCF2P-SBB200M5 NCF2P Yes CMB SVC 24X7X2OS CON-NCF4P-SBB200M5 NCF4P Yes CMB SVC 24X7X4OS

CON-NCF4S-SBB200M5 NCF4S Yes CMB SVC 8X5X4OS

CON-NCFCS-SBB200M5 NCFCS Yes CMB SVC 8X5XNBDOS

CON-NCF2-SBB200M5 NCF2 No CMB SVC 24X7X2

CON-NCFP-SBB200M5 NCFP No CMB SVC 24X7X4

CON-NCFE-SBB200M5 NCFE No CMB SVC 8X5X4

CON-NCFT-SBB200M5 NCFT No CMB SVC 8X5XNBD

CON-NCFW-SBB200M5 NCFW No CMB SVC SW

Note: For PID UCSB-B200-M5-U, select Service SKU with BB200M5U suffix (Example: CON-PREM- BB200M5U)

For PID UCSB-B200-M5-CH, select Service SKU with B200M5CH suffix (Example: CON-PREM- B200M5CH)

UCS Drive Retention Service With the Cisco Unified Computing Drive Retention Service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive.

Sophisticated data recovery techniques have made classified, proprietary, and confidential information vulnerable, even on malfunctioning disk drives. The Drive Retention service enables you to retain your drives and ensures that the sensitive data on those drives is not compromised, which reduces the risk of any potential liabilities. This service also enables you to comply with regulatory, local, and federal requirements.

Cisco UCS B200 M5 Blade Server 47 UCS B200 Ready2Ship Program

If your company has a need to control confidential, classified, sensitive, or proprietary data, you might want to consider one of the Drive Retention Services listed in the above tables (where available)

NOTE: Cisco does not offer a certified drive destruction service as part of this service.

Local Language Technical Support for UCS Where available, and subject to an additional fee, local language support for calls on all assigned severity levels may be available for specific product(s) – see tables above.

For a complete listing of available services for Cisco Unified Computing System, see the following URL: http://www.cisco.com/en/US/products/ps10312/serv_group_home.html

48 Cisco UCS B200 M5 Blade Server SUPPLEMENTAL MATERIAL

SUPPLEMENTAL MATERIAL

System Board A top view of the UCS B200 M5 system board is shown in Figure 5.

Figure 5 UCS B200 M5 System Board

1 Front mezzanine connector 2 USB connector (shown populated) An internal USB 3.0 port is supported. A 16 GB USB drive (UCS-USBFLSHB-16GB) is available from Cisco. A clearance of 0.950 inches (24.1 mm) is required for the USB device to be inserted and removed.

3 DIMM slots 4 CPU 1 socket (shown populated)

5 CPU heat sink install guide pins 6 CPU 2 socket (shown unpopulated)

7 Mini storage connector 8 Diagnostic button

9 mLOM connector 10 Rear mezzanine connector

Note: When the front mezzanine storage module is installed, the USB connector is underneath it. Use the small cutout opening in the storage module to visually determine the location of the USB connector when you need to insert a USB drive. When the NVIDIA GPU is installed in the front mezzanine slot, you cannot see the USB connector.

Cisco UCS B200 M5 Blade Server 49 SUPPLEMENTAL MATERIAL

Memory Configuration and Mirroring When the Memory Mirroring PID (N01-MMIRROR) is selected in Table 6 Available DDR4 DIMMs and PMEMs, page 16, the DIMMS will be placed as shown in Table 32 on page 53 by the factory

Each CPU has six DIMM channels:

■ CPU1 has channels A, B, C, D, E, and F ■ CPU2 has channels G, H, J, K, L, and M

Each DIMM channel has two slots: slot 1 and slot 2. The blue-colored DIMM slots are for slot 1 and the black slots for slot 2.

As an example, DIMM slots A1, B1, C1, D1, E1, and F1 belong to slot 1, while A2, B2, C2, D2, E2, and F2 belong to slot 2.

Figure 6 shows how slots and channels are physically laid out on the motherboard. The DIMM slots on the right half of the motherboard (channels A, B, C, D, E, and F) are associated with CPU 1, while the DIMM slots on the left half of the motherboard (channels G, H, J, K, L, and M) are associated with CPU 2. The slot 1 (blue) DIMM slots are always located farther away from a CPU than the corresponding slot 2 (black) slots.

Figure 6 Physical Layout of CPU DIMM Channels and Slots

For all allowable DIMM populations, please refer to the “Memory Population Guidelines” section of the B200 M5 Installation Guide, at the following link: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/hw/blade-servers/B200M5.p df

For more details, see the Cisco UCS C220/C240/B200 M5 memory Guide at the following link: https://www.cisco.com/c/dam/en/us/products/collateral/servers-unified-computing/ucs-c-se ries-rack-servers/memory-guide-c220-c240-b200-m5.pdf

When considering the memory configuration of your server, consider the following items:

■ Each channel has two DIMM slots (for example, channel A = slots A1 and A2). — A channel can operate with one or two DIMMs installed. ■ When both CPUs are installed, populate the DIMM slots of each CPU identically. ■ Any DIMM installed in a DIMM socket for which the CPU is absent is not recognized.

50 Cisco UCS B200 M5 Blade Server SUPPLEMENTAL MATERIAL

■ Observe the DIMM mixing rules shown in Table 31.

Table 31 DIMM Rules for B200 M5 Servers

DIMM Parameter DIMMs in the Same Channel DIMM in the Same Slot1

DIMM Capacity DIMMs in the same channel (for For best performance, DIMMs in example, A1 and A2) can have the same slot (for example, A1, RDIMM = 16, 32, or 64 GB B1, C1, LRDIMM = 32, 64, or 128 GB different capacities. D1, E1, F1) should have the same capacity. TSV-RDIMM = 64 or 128 GB,

Do not mix TSV-RDIMMS with Do not mix TSV-RDIMMS with LRDIMMs nor RDIMMs LRDIMMs nor RDIMMs

DIMM Speed 2933- or DIMMs will run at the lowest DIMMs will run at the lowest speed 2666-MHz speed of the CPU installed of the CPU installed

DIMM Type Do not mix DIMM types in a Do not mix DIMM types in a slot TSV-RDIMMS, RDIMMs, or channel LRDIMMs

Notes: 1. Although different DIMM capacities can exist in the same slot, this will result in less than optimal performance. For optimal performance, all DIMMs in the same slot should be identical.

■ The DIMM/PMEM guidelines are as follows: — All DDR4 DIMMs populated in the DIMM slots must be the same size. — If you select any PMEMs, you must also select two CPUs and 12 DIMMs. You can have 4, 8, or 12 PMEMs, but you must select 12 DIMMs any time you select PMEMs. — PMEMs populated in the DIMM slots must all be the same size. PMEM size mixing is not allowed (for example, you cannot mix 512 GB and 128 GB PMEMs within the same server). — You cannot select more than 1024 GB of PMEM memory per CPU for non “L” series CPUs. — The PMEMs run at 2666 MHz. If you have 2933-MHz RDIMMs or LRDIMMs in the server and you add PMEMs, the main memory speed clocks down to 2666 MHz to match the speed of the PMEMs. — The recommended DIMM:PMEM capacity ratio is from 1:2 through 1:16. — Both PMEM operational modes (App Direct and Memory Mode) are compatible with the B200 M5. — Using non-Cisco supported hardware configurations may result in slower performance or a non-supported warning during bootup.

Cisco UCS B200 M5 Blade Server 51 SUPPLEMENTAL MATERIAL

Memory Mirroring When Memory Mirroring PID (N01-MMIRROR) is selected in STEP 3 CHOOSE MEMORY, page 15, the DIMMS will be placed by the factory as shown in the Table 32. ■ Select 4, 6, 8, or 12 identical DIMMS per CPU. ■ If only 1 CPU is selected, please refer only to the CPU 1 DIMM placement columns in the Table 32. Table 32 Memory Mirroring DIMM CPU 1 DIMM Placement in Channels CPU 2 DIMM Placement in Channels Rank (for identical ranked DIMMS) (for identical ranked DIMMS) 4 (A1, B1); (D1, E1) (G1, H1); (K1, L1)

6 (A1, B1); (C1, D1); (E1, F1) (G1, H1); (J1, K1); (L1, M1)

8 (A1, B1); (D1, E1); (A2, B2); (D2, E2) (G1, H1); (K1, L1); (G2, H2); (K2, L2) (A1, B1); (C1, D1); (E1, F1); (A2, B2); (C2, D2); (G1, H1); (J1, K1); (L1, M1); (G2, H2); (J2, K2); 12 (E2, F2) (L2, M2)

52 Cisco UCS B200 M5 Blade Server SUPPLEMENTAL MATERIAL

Memory Support for CPU Classes and CPU Modes

For 2nd Generation Intel® Xeon® Scalable Processors: ■ DIMMs and PMEMs are supported ■ CPU PIDs ending in “M” support up to a limit of 2048 GB per CPU ■ CPU PIDs ending in “L” support up to a limit of 4608 GB per CPU ■ All other CPU PIDs support up to a limit of 1024 GB per CPU ■ For the App Direct Mode, both PMEM and DIMM capacities count towards the CPU capacity limit ■ For the Memory Mode and Mixed Mode only the PMEM capacity counts towards the CPU capacity limit

For Configurations Using Only DIMMs ■ CPU PIDs ending in “M” support DIMM capacities up to 1536 GB per CPU (using 12 x 128 GB DIMMs) and DIMM capacities up to 2048 GB per CPU (using 8 x 256 GB DIMMs). ■ CPU PIDs ending in “L” support DIMM capacities up to 1536 GB per CPU (using 12 x 128 GB DIMMs) and DIMM capacities up to 3072 GB per CPU (using 12 x 256 GB DIMMs). The 4608 GB limit cannot be reached with these capacity DIMMs. ■ CPU PIDs not ending in “L” or “M” support DIMM capacities up to 1024 GB per CPU (using 8 x 128 GB DIMMs or 4 x 256 GB DIMMs).

For Configurations Using DIMMs and PMEMs in App Direct Mode ■ CPU PIDs ending in “M” support capacities up to 1792 GB per CPU (using 6 x 128 GB DIMMS and 2 x 512 GB PMEMs or 4 x 256 GB PMEMs) or up to 2048 GB per CPU (using 6 x 256 GB DIMMs and 2 x 256 GB PMEMs or 6 x 256 GB DIMMs and 4 x 128 GB PMEMs) ■ CPU PIDs ending in “L” support capacities up to 3840 GB per CPU (using 6 x 128 GB DIMMs and 6 x 512 GB PMEMs) or up to 4608 GB per CPU (using 6 x 256 GB DIMMs and 6 x 512 GB PMEMs) ■ CPU PIDs not ending in “L” or “M” support capacities up to 1024 GB per CPU (using 6 x 128 GB DIMMs and 2 x 128 GB PMEMs).

For Configurations Using DIMMs and PMEMs in Memory or Mixed Mode

NOTE: For Memory and Mixed Modes, DIMMs are used as cache and do not factor into CPU capacity.

■ CPU PIDs ending in “M” support capacities up to 2048 GB per CPU using: — 6 x 128 GB DIMMs as cache and 4 x 512 GB PMEMs as memory, or — 6x 256 GB DIMMs as cache and 4 x 512 GB PMEMs as memory ■ CPU PIDs ending in “L” support capacities up to 3072 GB using: — 6 x 128 GB DIMMs as cache and 6 x 512 GB PMEMs as memory, or

Cisco UCS B200 M5 Blade Server 53 SUPPLEMENTAL MATERIAL

— 6 x 256 GB DIMMs as cache and 6 x 512 GB PMEMs as memory

The allowable 4608 limit for PMEM capacity is not reached in this case.

■ CPU PIDs not ending in “L” or “M” support capacities up to 1024 GB per CPU using: — 6 x 128 GB DIMMs as cache and 2 x 512 GB PMEMs as memory, or — 6 x 256 GB DIMMs as cache and 2 x 512 GB PMEMs as memory

For Intel® Xeon® Scalable Processors: ■ DIMMs are supported; PMEMs are not supported ■ CPU PIDs ending in “M' support DIMM capacities up to 1536 GB per CPU (using 12 x 128 GB DIMMs). ■ All other CPU PIDs support DIMM capacities up to 768 GB per CPU (using 6 x 128 GB DIMMs or 12 x 64 GB DIMMs)

54 Cisco UCS B200 M5 Blade Server SPARE PARTS

SPARE PARTS

This section lists the upgrade and service-related parts for the UCS B200 M5 server. Some of these parts are configured with every server or with every UCS 5108 blade server chassis.

Table 33 Spare Parts

Product ID (PID) PID Description

Packaging Kit

UCSB-10-PK-M5BLADE MULTI: 10-PK B200 M5 W/BLANKING PANELS, PACKAGING KIT

UCSB-B200-PKG= UCSB B200 Packaging (M2, M3, M4, M5)

Local KVM I/O Cable

N20-BKVM= KVM local IO cable for UCS servers console port

CPU Accessories

UCSB-HS-M5-F= CPU Heat Sink for UCS B-Series M5 CPU socket (Front)

UCSB-HS-M5-R= CPU Heat Sink for UCS B-Series M5 CPU socket (Rear)

UCS-CPU-TIM= Single CPU thermal interface material syringe for M5 server HS seal

UCSX-HSCK= UCS Processor Heat Sink Cleaning Kit (when replacing a CPU)2

UCS-CPUAT= CPU Assembly Tool for M5 Servers

UCS-M5-CPU-CAR= UCS M5 CPU Carrier

Memory

UCS-DIMM-BLK UCS DIMM Blanks

UCS-ML-X64G4RT-H= 64 GB DDR4-2933-MHz LRDIMM/4Rx4 (8Gb) 1.2v

UCS-MR-X64G2RT-H= 64 GB DDR4-2933-MHz RDIMM/2Rx4 (16Gb) 1.2v

Storage Controller

UCSB-MRAID-SC= Supercap for FlexStorage 12G SAS RAID controller w/1GB FBWC

UCSB-MRAID12G= Cisco FlexStorage 12G SAS RAID controller with drive bays

UCSB-MRAID12G-HE= Cisco FlexStorage 12G SAS RAID controller with 2 GB flash-backed write cache and drive bays

UCSB-LSTOR-PT= Cisco FlexStorage Passthrough module w/drive bays

UCSB-LSTOR-BK= Cisco FlexStorage blanking panel w/o controller, w/o drive bays

Drives

HDDs

HDDs (15K RPM)

Cisco UCS B200 M5 Blade Server 55 SPARE PARTS

Table 33 Spare Parts

UCS-HD300G15K12G= 300 GB 12G SAS 15K RPM SFF HDD

UCS-HD600G15K12G= 600 GB 12G SAS 15K RPM SFF HDD

UCS-HD900G15K12G= 900 GB 12G SAS 15K RPM SFF HDD

HDDs (10K RPM)

UCS-HD300G10K12G= 300 GB 12G SAS 10K RPM SFF HDD

UCS-HD600G10K12G= 600 GB 12G SAS 10K RPM SFF HDD

UCS-HD12TB10K12G= 1.2 TB 12G SAS 10K RPM SFF HDD

UCS-HD18TB10KS4K= 1.8 TB 12G SAS 10K RPM SFF HDD (4K)

UCS-HD24TB10KS4K= 2.4 TB 12G SAS 10K RPM SFF HDD (4K)

Enterprise Performance SSDs (High endurance, supports up to 10X or 3X DWPD (drive writes per day))

SAS SSDs

UCS-SD800GSAS3-EP= 800GB 2.5 inch Enterprise performance 12G SAS SSD(3X endurance) (Toshiba PX05)

UCS-SD16TH3-EP= 1.6TB 2.5 inch Enterprise performance 12G SAS SSD (3X DWPD)

UCS-SD32TH3-EP= 3.2TB 2.5in Enterprise performance 12G SAS SSD (3X DWPD)

UCS-SD800GKB3X-EP= 800GB 2.5in Enterprise Performance 12G SAS SSD(3X endurance)

UCS-SD16TKB3X-EP= 1.6TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance)

UCS-SD32TKB3X-EP= 3.2TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance)

SATA SSDs

UCS-SD480GIS3-EP= 480GB 2.5in Enterprise performance 6G SATA SSD(3X endurance) (Intel S4600)

UCS-SD960GIS3-EP= 960GB 2.5in Enterprise performance 6G SATA SSD(3X endurance) (Intel S4600)

UCS-SD19TIS3-EP= 1.9TB 2.5in Enterprise performance 6G SATA SSD(3X endurance) (Intel S4600)

UCS-SD16TB12S3-EP= 1.6TB 2.5 inch Ent. Performance 6GSATA SSD(3X endurance)

UCS-SD800G12S3-EP= 800GB 2.5 inch Enterprise performance 6G SATA SSD(3 FWPD)

UCS-SD200G12S3-EP= 200GB 2.5 inch Enterprise performance 6G SATA SSD(3 FWPD)

UCS-SD480GMB3X-EP= 480GB 2.5in Enterprise performance 6GSATA SSD(3X endurance)

UCS-SD960GMB3X-EP= 960GB 2.5in Enterprise performance 6GSATA SSD(3X endurance)

UCS-SD19TMB3X-EP= 1.9TB 2.5in Enterprise performance 6GSATA SSD(3X endurance)

Enterprise Value (Low endurance, supports up to 1X DWPD (drive writes per day))

UCS-SD960GBKS4-EV= 960 GB 2.5 inch Enterprise Value 6G SATA SSD (Samsung PM863A/PM883)

UCS-SD38TBKS4-EV= 3.8 TB 2.5 inch Enterprise Value 6G SATA SSD (Samsung PM863A/PM883)

56 Cisco UCS B200 M5 Blade Server SPARE PARTS

Table 33 Spare Parts

UCS-SD120GBMS4-EV= 120 GB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100/5200)

UCS-SD240GBMS4-EV= 240 GB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100/5200)

UCS-SD480GBMS4-EV= 480 GB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100/5200)

UCS-SD76TBMS4-EV= 7.6 TB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100/5200)

UCS-SD480GBIS6-EV= 480 GB 2.5 inch Enterprise Value 6G SATA SSD (Intel S4500/S4150)

UCS-SD960GBIS6-EV= 960 GB 2.5 inch Enterprise Value 6G SATA SSD (Intel S4500/S4150)

UCS-SD38TBIS6-EV= 3.8 TB 2.5 inch Enterprise Value 6G SATA SSD (Intel S4500/S4150)

UCS-SD960GKB1X-EV= 960GB 2.5 inch Enterprise Value 12G SAS SSD

UCS-SD19TKB1X-EV= 1.9TB 2.5 inch Enterprise Value 12G SAS SSD

UCS-SD38TKB1X-EV= 3.8TB 2.5 inch Enterprise Value 12G SAS SSD

UCS-SD76TKB1X-EV= 7.6TB 2.5 inch Enterprise Value 12G SAS SSD

UCS-SD15TKB1X-EV= 15.3TB 2.5 inch Enterprise Value 12G SAS SSD

Self-Encrypted Drives (SED)

UCS-HD600G15K9= 600GB 12G SAS 15K RPM SFF HDD (SED)

UCS-HD18G10K9= 1.8TB 12G SAS 10K RPM SFF HDD (4K format, SED)

UCS-HD24T10BNK9= 2.4 TB 12G SAS 10K RPM SFF HDD (4K) SED

NVMe1,2,3

UCSB-NVMEHW-I8000= Cisco 2.5" U.2 8TB Intel P4510 NVMe High Perf. Value Endurance

UCSB-NVMEXPB-I375= Cisco 2.5in U.2 375GB Intel P4800 NVMe Med. Perf

UCSB-NVMEXP-I750= 750 GB 2.5in Intel Optane NVMe Extreme Perf

UCSB-NVME2H-I2TBV= Cisco 2.5" U.2 2.0TB Intel P4510 NVMe High Perf. Value Endurance

UCSB-NVME2H-I1000= Cisco 2.5" U.2 1,0 TB Intel P4510 NVMe High Perf. Value Endu

UCSB-NVME2H-I1600= Cisco 2.5" U.2 1.6TB Intel P4610 NVMe High Perf. High Endu

UCSB-NVME2H-I3200= Cisco 2.5" U.2 3.2TB Intel P4610 NVMe High Perf. High Endurance

UCSB-NVME2H-I4000= Cisco 2.5" U.2 4.0TB Intel P4510 NVMe High Perf. Value Endu

Supported Mezzanine cards

UCSB-MLOM-40G-04= UCS VIC 1440 modular LOM for blade servers mLOM

UCSB-MLOM-40G-03= UCS VIC 1340 modular LOM for blade servers mLOM

UCSB-VIC-M84-4P= Cisco UCS VIC 1480 mezzanine adapter Rear Mezzanine

UCSB-VIC-M83-8P= Cisco UCS VIC 1380 mezzanine adapter

Cisco UCS B200 M5 Blade Server 57 SPARE PARTS

Table 33 Spare Parts

Port Expander Card for VIC option

UCSB-MLOM-PT-01= Cisco UCS Port Expander Card for VIC.

GPUs

UCSB-GPU-P6-F= NVIDIA GRID P6 Front Mezzanine

UCSB-GPU-P6-R= NVIDIA GRID P6 Rear Mezzanine

Cisco Storage Accelerators

UCSB-F-H-5607= UCS Blade PCIe/NVMe Storage Mezz 560 GB High Endurance

UCSB-F-H-32003= UCS Blade PCIe/NVMe Storage Mezz 3200 GB Medium Endurance

Trusted Platform Module

UCSX-TPM2-001= Trusted Platform Module for UCS (SPI-based)

UCSX-TPM2-002= Trusted Platform Module 2.0 for UCS servers

UCSX-TPM2-002B= Trusted Platform Module2.0 M5 UCS svr (FIPS 140-2 Compliant)

Secure Digital Cards

UCS-SD-128G= 128 GB SD Card for UCS servers

UCS-SD-64G-S= 64 GB SD Card for UCS servers

UCS-SD-32G-S= 32 GB SD Card for UCS servers

UCS-MSTOR-SD= SD module card (holds up to 2)

M.2 SATA SSDs

UCS-M2-240GB= 240 GB M.2 SATA SSD

UCS-MSTOR-M2= M.2 module card (holds up to 2)

Boot-Optimized RAID controller

UCS-M2-HWRAID = Cisco Boot optimized M.2 Raid controller

USB 3.0 Drive

UCS-USBFLSHB-16GB UCS Servers 16 GB Flash USB Drive

Power Cables

CAB-C13-C14-2M= CABASY,WIRE,JUMPER CORD, PWR, 2 Meter, C13/C14,10A/250V

CAB-250V-10A-AR= Power Cord, SFS, 250V, 10A, Argentina

CAB-9K10A-AU= Power Cord, 250VAC 10A 3112 Plug, Australia

CAB-250V-10A-CN= AC Power Cord - 250V, 10A - PRC

CAB-9K10A-EU= Power Cord, 250VAC 10A CEE 7/7 Plug, EU

58 Cisco UCS B200 M5 Blade Server SPARE PARTS

Table 33 Spare Parts

CAB-250V-10A-ID= Power Cord, SFS, 250V, 10A, India

CAB-250V-10A-IS= Power Cord, SFS, 250V, 10A, Israel

CAB-9K10A-IT= Power Cord, 250VAC 10A CEI 23-16/VII Plug, Italy

CAB-9K10A-SW= Power Cord, 250VAC 10A MP232 Plug, Switzerland

CAB-9K10A-UK= Power Cord, 250VAC 10A BS1363 Plug (13 A fuse), UK

CAB-AC-L620-C13= AC Power Cord, NEMA L6-20 - C13, 2M/6.5ft

CAB-250V-10A-BR= Power Cord - 250V, 10A - Brazil

Software/Firmware

IMC Supervisor

CIMC-SUP-BASE-K9= IMC Supervisor One-time Site Installation License

CIMC-SUP-B01= IMC Supervisor-Branch Mgt SW for C-Series & E-Series up to 100 Svrs

CIMC-SUP-B02= IMC Supervisor- Branch Mgt SW for C & E-Series up to 250 Svrs

CIMC-SUP-B10= IMC Supervisor- Branch Mgt SW for C & E-Series up to 1K Svrs

CIMC-SUP-B25= IMC Supervisor Branch Mgt SW for C & E-Series 25 Svrs

CIMC-SUP-A01= IMC Supervisor Adv-Branch Mgt SW for C & E-Series 100 Svrs

CIMC-SUP-A02= IMC Supervisor Adv-Branch Mgt SW for C & E-Series 250 Svrs

CIMC-SUP-A10= IMC Supervisor Adv-Branch Mgt SW for C & E-Series 1000 Svrs

CIMC-SUP-A25= IMC Supervisor Adv-Branch Mgt SW for C & E-Series 250 Svrs

EVAL-CIMC-SUP= EVAL: IMC Supervisor-Branch Mgt SW for C/E-Series - 50 Svrs

EVAL-CIMC-SUP-BAS= EVAL: IMC Supervisor One-time Site Installation License

UCS Multi-Domain Manager

UCS-MDMGR-1S= UCS Central Per Server License

NOTE: IF you must order quantity greater than 1 of UCS-MDMGR-1S, you need to reference the UCS Central Per Server Data Sheet to order the standalone PIDs: UCS-MDMGR-LIC= or UCS-MDMGR-1DMN=

VMware vCenter

VMW-VCS-STD-1A= VMware vCenter 6 Server Standard, 1 yr support required

VMW-VCS-STD-3A= VMware vCenter 6 Server Standard, 3 yr support required

VMW-VCS-STD-5A= VMware vCenter 6 Server Standard, 5 yr support required

VMW-VCS-FND-1A= VMware vCenter 6 Server Foundation (3 Host), 1 yr supp reqd

VMW-VCS-FND-3A= VMware vCenter 6 Server Foundation (3 Host), 3 yr supp reqd

VMW-VCS-FND-5A= VMware vCenter 6 Server Foundation (3 Host), 5 yr supp reqd

Cisco UCS B200 M5 Blade Server 59 SPARE PARTS

Table 33 Spare Parts

Red Hat

RHEL-2S2V-1A= Red Hat Enterprise Linux (1-2 CPU,1-2 VN)

RHEL-2S2V-3A= Red Hat Enterprise Linux (1-2 CPU,1-2 VN)

RHEL-2S2V-1S= Red Hat Enterprise Linux (1-2 CPU,1-2 VN)

RHEL-2S2V-3S= Red Hat Enterprise Linux (1-2 CPU,1-2 VN)

RHEL-2S-HA-1S= RHEL High Availability (1-2 CPU)

RHEL-2S-HA-3S= RHEL High Availability (1-2 CPU)

RHEL-2S-RS-1S= RHEL Resilient Storage (1-2 CPU)

RHEL-2S-RS-3S= RHEL Resilient Storage (1-2 CPU)

RHEL-2S-SFS-1S= RHEL Scalable File System (1-2 CPU)

RHEL-2S-SFS-3S= RHEL Scalable File System (1-

RHEL-2S2V-5A= Red Hat Enterprise Linux (1-2 CPU,1-2 VN)

RHEL-2S-HA-1A= RHEL High Availability (1-2 CPU)

RHEL-2S-HA-3A= RHEL High Availability (1-2 CPU)

RHEL-2S-HA-5A= RHEL High Availability (1-2 CPU)

RHEL-2S-RS-1A= RHEL Resilent Storage (1-2 CPU)

RHEL-2S-RS-3A= RHEL Resilent Storage (1-2 CPU)

RHEL-2S-RS-5A= RHEL Resilent Storage (1-2 CPU)

RHEL-2S-SFS-1A= RHEL Scalable File System (1-2 CPU)

RHEL-2S-SFS-3A= RHEL Scalable File System (1-2 CPU)

RHEL-2S-SFS-5A= RHEL Scalable File System (1-2 CPU)

Red Hat SAP

RHEL-SAP-2S2V-1S= RHEL for SAP Apps (1-2 CPU, 1-2 VN); Prem 1-Yr SnS Reqd

RHEL-SAP-2S2V-3S= RHEL for SAP Apps (1-2 CPU, 1-2 VN); Prem 3-Yr SnS Reqd

RHEL-SAPSP-3S= RHEL SAP Solutions Premium - License with 3 Years of SnS

RHEL-SAPSS-3S= RHEL SAP Solutions Standard - License with 3 Years of SnS

VMware

VMW-VSP-STD-1S= VMware vSphere 6 Standard (1 CPU), 1-yr Vmware SnS Reqd

VMW-VSP-STD-3S= VMware vSphere 6 Standard (1 CPU), 3-yr Vmware SnS Reqd

VMW-VSP-EPL-1S= VMware vSphere 6 Ent Plus (1 CPU), 1-yr Vmware SnS Reqd

60 Cisco UCS B200 M5 Blade Server SPARE PARTS

Table 33 Spare Parts

VMW-VSP-EPL-3S= VMware vSphere 6 Ent Plus (1 CPU), 3-yr Vmware SnS Reqd

VMW-VSP-STD-1A= VMware vSphere 6 Standard (1 CPU), 1-yr, Support Required

VMW-VSP-STD-3A= VMware vSphere 6 Standard (1 CPU), 3-yr, Support Required

VMW-VSP-STD-5A= VMware vSphere 6 Standard (1 CPU), 5-yr, Support Required

VMW-VSP-EPL-3A= VMware vSphere 6 Ent Plus (1 CPU), 3-yr, Support Required

VMW-VSP-EPL-1A= VMware vSphere 6 Ent Plus (1 CPU), 1-yr, Support Required

VMW-VSP-EPL-5A= VMware vSphere 6 Ent Plus (1 CPU), 5-yr, Support Required

SLES and SAP

SLES-SAP-2S2V-1A= SLES for SAP Apps (1-2 CPU, 1-2 VM)

SLES-SAP-2SUV-1A= SLES for SAP Apps (1-2 CPU, Unl VM)

SLES-SAP-2S2V-3A= SLES for SAP Apps (1-2 CPU, 1-2 VM)

SLES-SAP-2SUV-3A= SLES for SAP Apps (1-2 CPU, Unl VM)

SLES-SAP-2S2V-5A= SLES for SAP Apps (1-2 CPU, 1-2 VM)

SLES-SAP-2SUV-5A= SLES for SAP Apps (1-2 CPU, Unl VM)

SLES-SAP-2S2V-1S= SLES for SAP Apps (1-2 CPU, 1-2 VM)

SLES-SAP-2SUV-1S= SLES for SAP Apps (1-2 CPU, Unl VM)

SLES-SAP-2S2V-3S= SLES for SAP Apps (1-2 CPU, 1-2 VM)

SLES-SAP-2SUV-3S= SLES for SAP Apps (1-2 CPU, Unl VM)

SLES-SAP-2S2V-5S= SLES for SAP Apps (1-2 CPU, 1-2 VM)

SLES-SAP-2SUV-5S= SLES for SAP Apps (1-2 CPU, Unl VM)

SUSE

SLES-2S2V-1A= SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM)

SLES-2SUV-1A= SUSE Linux Enterprise Svr (1-2 CPU,Unl VM)

SLES-2S2V-3A= SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM)

SLES-2SUV-3A= SUSE Linux Enterprise Svr (1-2 CPU,Unl VM)

SLES-2S2V-5A= SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM)

SLES-2SUV-5A= SUSE Linux Enterprise Svr (1-2 CPU,Unl VM)

SLES-2S2V-1S= SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM)

SLES-2SUV-1S= SUSE Linux Enterprise Svr (1-2 CPU,Unl VM)

SLES-2S2V-3S= SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM)

Cisco UCS B200 M5 Blade Server 61 SPARE PARTS

Table 33 Spare Parts

SLES-2SUV-3S= SUSE Linux Enterprise Svr (1-2 CPU,Unl VM)

SLES-2S2V-5S= SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM)

SLES-2SUV-5S= SUSE Linux Enterprise Svr (1-2 CPU,Unl VM)

SLES-2S-HA-1S= SUSE Linux High Availability Ext (1-2 CPU)

SLES-2S-HA-3S= SUSE Linux High Availability Ext (1-2 CPU)

SLES-2S-HA-5S= SUSE Linux High Availability Ext (1-2 CPU)

SLES-2S-GC-1S= SUSE Linux GEO Clustering for HA (1-2 CPU)

SLES-2S-GC-3S= SUSE Linux GEO Clustering for HA (1-2 CPU)

SLES-2S-GC-5S= SUSE Linux GEO Clustering for HA (1-2 CPU)

SLES-2S-LP-1S= SUSE Linux Live Patching Add-on (1-2 CPU)

SLES-2S-LP-3S= SUSE Linux Live Patching Add-on (1-2 CPU)

Notes: 1. NVMe drives require the following storage controller in the front mezzanine slot: UCSB-LSTOR-PT 2. For HDD or SSD drives to be in a RAID group, two identical HDDs or SSDs must be used in the group. 3. If HDD or SSD are in JBOD Mode, the drives do not need to be identical.

Please refer to the UCS B200 M5 Installation Guide for installation procedures.

62 Cisco UCS B200 M5 Blade Server UPGRADING or REPLACING CPUs

UPGRADING or REPLACING CPUs

NOTE: Before servicing any CPU, do the following: ■ Decommission and power off the server. ■ Slide the B200 M5 out from its chassis. ■ Remove the top cover.

To replace an existing CPU, follow these steps:

(1) Have the following tools and materials available for the procedure:

■ T-30 Torx driver—Supplied with replacement CPU. ■ #1 flat-head screwdriver—Supplied with replacement CPU. ■ CPU assembly tool—Supplied with replacement CPU. Can be ordered separately as Cisco PID UCS-CPUAT=. ■ Heatsink cleaning kit—Supplied with replacement CPU. Can be ordered separately as Cisco PID UCSX-HSCK=. ■ Thermal interface material (TIM)—Syringe supplied with replacement CPU. Can be ordered separately as Cisco PID UCS-CPU-TIM=.

(2) Order the appropriate replacement CPU from Available CPUs on page 10.

(3) Carefully remove and replace the CPU and heatsink in accordance with the instructions found in “Cisco UCS B200 M5 Blade Server Installation and Service Note,” found at: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/hw/blade-servers/B200M5/B200 M5_chapter_011.html#id_104667.

To add a new CPU, follow these steps:

(1) Have the following tools and materials available for the procedure:

■ T-30 Torx driver—Supplied with new CPU. ■ #1 flat-head screwdriver—Supplied with new CPU ■ CPU assembly tool—Supplied with new CPU.Can be ordered separately as Cisco PID UCS-CPUAT= ■ Thermal interface material (TIM)—Syringe supplied with replacement CPU.Can be ordered separately as Cisco PID UCS-CPU-TIM=

(2) Order the appropriate new CPU from Table 4 on page 10.

(3) Order one heat sink for each new CPU. Order PID UCSB-HS-M5-F= for the front CPU socket and PID UCSB-HS-M5-R= for the rear CPU socket.

Cisco UCS B200 M5 Blade Server 63 UPGRADING or REPLACING MEMORY

(4) Carefully install the CPU and heatsink in accordance with the instructions found in “Cisco UCS B200 M5 Blade Server Installation and Service Note,” found at: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/hw/blade-servers/B200M5/B200 M5_chapter_011.html#id_104667.

UPGRADING or REPLACING MEMORY

NOTE: Before servicing any DIMM or PMEM, do the following: ■ Decommission and power off the server. ■ Remove the top cover from the server ■ Slide the server out the front of the chassis.

To add or replace DIMMs or PMEMs, follow these steps:

(1) Order new DIMMs or PMEMs as needed from Table 6 on page 16.

(2) Order DIMM/PMEM blanks as needed (PID UCS-DIMM-BLK=)

(3) Open both connector latches and remove and replace the DIMM/PMEM or blank as needed.

Figure 7 Replacing Memory

64 Cisco UCS B200 M5 Blade Server UPGRADING or REPLACING MEMORY

(4) Press evenly on both ends of the DIMM/PMEM until it clicks into place in its slot.

NOTE: Ensure that the notch in the DIMM/PMEM aligns with the slot. If the notch is misaligned, it is possible to damage the DIMM/PMEM, the slot, or both.

(5) Press the connector latches inward slightly to seat them fully.

(6) Populate all slots with a DIMM, PMEM, or DIMM blank. A slot cannot be empty.

For additional details on replacing or upgrading DIMMs, see “Cisco UCS B200 M5 Blade Server Installation and Service Note,” found at https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/hw/blade-servers/B200M5/B 200M5_chapter_011.html#concept_on5_vzl_kz.

Cisco UCS B200 M5 Blade Server 65 DISCONTINUED EOL PRODUCTS

DISCONTINUED EOL PRODUCTS

Below is the list of parts were previously available for this product and are no longer sold. Please refer to the EOL bulletin links shown in Table 34 to determine if the part is still supported and if there is a replacement part.

Table 34 EOL Products

EOS option PID Description EOL Bulletin Link DRIVES Enterprise Value SSDs UCS-SD150GBKS4-EV 150 GB 2.5 inch Enterprise Value 6G https://www.cisco.com/c/en/us/products/collate SATA SSD ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-740779.html UCS-SD480GBKS4-EV 480 GB 2.5 inch Enterprise Value 6G https://www.cisco.com/c/en/us/products/collate SATA SSD ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-740779.html UCS-SD960GIKS4-EV 960GB 2.5 inch Enterprise Value 6G SATA https://www.cisco.com/c/en/us/products/collate SSD ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-740779.html UCS-SD16TBKS4-EV 1.6TB 2.5 inch Enterprise Value 6G SATA https://www.cisco.com/c/en/us/products/collate SSD ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-740779.html HX-SD480GBKSS-EV 480GB 2.5 in Enterprise Value 6G SATA https://www.cisco.com/c/en/us/products/collate SSD(1FWPD)-PM86 ral/servers-unified-computing/ucs-b-series-blade-s ervers/eos-eol-notice-c51-742066.html UCS-SD240GBKS4-EV 240GB 2.5 inch Enterprise Value 6G SATA https://www.cisco.com/c/en/us/products/collate SSD ral/servers-unified-computing/ucs-b-series-blade-s ervers/eos-eol-notice-c51-742066.html UCS-SD480GBKSS-EV 480GB 2.5 in Enterprise Value 6G SATA https://www.cisco.com/c/en/us/products/collate SSD(1FWPD)-PM86 ral/servers-unified-computing/ucs-b-series-blade-s ervers/eos-eol-notice-c51-742066.html UCS-SD38T2HBNK9 3.8TB Enterprise value SAS SSD (1X https://www.cisco.com/c/en/us/products/collate FWPD, SED) ral/hyperconverged-infrastructure/hyperflex-hx-se ries/eos-eol-notice-c51-2451489.html UCS-SD480GH1-EV 480 GB 2.5 inch Enterprise Value 12G https://www.cisco.com/c/en/us/products/collate SAS SSD (1X endurance) ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-743832.html UCS-HD12G10K9 1.2 TB 12G SAS 10K RPM SFF HDD (SED) UCS-SD19TH1-EV 1.9 TB 2.5 inch Enterprise Value 12G SAS https://www.cisco.com/c/en/us/products/collate SSD (1X endurance) ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-743832.html UCS-SD960GBHBNK9 960 GB Enterprise value SAS SSD (1X https://www.cisco.com/c/en/us/products/collate FWPD, SED) FIPS 140-2 ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-742823.html UCS-SD38TH1-EV 3.8 TB 2.5 inch Enterprise Value 12G SAS https://www.cisco.com/c/en/us/products/collate SSD (1X endurance) ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-743832.html

66 Cisco UCS B200 M5 Blade Server DISCONTINUED EOL PRODUCTS

Table 34 EOL Products (continued)

EOS option PID Description EOL Bulletin Link UCS-SD19TSAS-EV 1.9 TB 2.5 inch Enterprise Value 12G SAS https://www.cisco.com/c/en/us/products/collate SSD ral/hyperconverged-infrastructure/hyperflex-hx-se ries/eos-eol-notice-c51-2451489.html UCS-SD960GSAS-EV 960 GB 2.5 inch Enterprise Value 12G https://www.cisco.com/c/en/us/products/collate SAS SSD (Toshiba PX05) ral/hyperconverged-infrastructure/hyperflex-hx-se ries/eos-eol-notice-c51-2451489.html UCS-SD38TSAS-EV 3.8 TB 2.5 inch Enterprise Value 12G SAS https://www.cisco.com/c/en/us/products/collate SSD (Toshiba PX05) ral/hyperconverged-infrastructure/hyperflex-hx-se ries/eos-eol-notice-c51-2451489.html UCS-SD960GH1-EV 960 GB 2.5 inch Enterprise Value 12G https://www.cisco.com/c/en/us/products/collate SAS SSD (1X endurance) ral/hyperconverged-infrastructure/hyperflex-hx-se ries/eos-eol-notice-c51-2451489.html UCS-SD480GSAS-EV 480 GB 2.5 inch Enterprise Value 12G https://www.cisco.com/c/en/us/products/collate SAS SSD (Toshiba PX05) ral/hyperconverged-infrastructure/hyperflex-hx-se ries/eos-eol-notice-c51-2451489.html Enterprise Performance SSDs UCS-SD200G12S3-EP 200GB 2.5 inch Enterprise performance https://www.cisco.com/c/en/us/products/collate 6G SATA SSD(3 FWPD) ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-739513.html UCS-SD480G12S3-EP 480GB 2.5 inch Ent. Performance https://www.cisco.com/c/en/us/products/collate 6GSATA SSD(3X endurance) ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-739513.html UCS-SD800G12S3-EP 800GB 2.5 inch Enterprise performance https://www.cisco.com/c/en/us/products/collate 6G SATA SSD(3 FWPD) ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-739513.html UCS-SD16TB12S3-EP 1.6TB 2.5 inch Ent. Performance 6GSATA https://www.cisco.com/c/en/us/products/collate SSD(3X endurance) ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-739513.html UCS-SD400GH3-EP 400GB 2.5 inch Enterprise performance https://www.cisco.com/c/en/us/products/collate 12G SAS SSD (3X DWPD) ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-739513.html UCS-SD400G12S4-EP 400 GB 2.5 inch Ent Performance 12G https://www.cisco.com/c/en/us/products/collate SAS SSD (10X endurance) (SanDisk ral/servers-unified-computing/ucs-c-series-rack-se Lightning II) rvers/eos-eol-notice-c51-739513.html UCS-SD800G12S4-EP 800 GB 2.5 inch Ent. Performance 12G https://www.cisco.com/c/en/us/products/collate SAS SSD (10X endurance) (Samsung 1635) ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-741644.html UCS-SD16TB12S4-EP 1.6 TB 2.5 inch Ent. Performance 12G https://www.cisco.com/c/en/us/products/collate SAS SSD (10X endurance) (SanDisk ral/servers-unified-computing/ucs-c-series-rack-se Lightning II) rvers/eos-eol-notice-c51-741644.html UCS-SD800GH3-EP 800GB 2.5 inch Enterprise performance https://www.cisco.com/c/en/us/products/collate 12G SAS SSD (3X DWPD) ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-743832.html UCS-SD16TSASS3-EP 1.6TB 2.5 inch Enterprise performance https://www.cisco.com/c/en/us/products/collate 12G SAS SSD(3X endurance) (Toshiba ral/hyperconverged-infrastructure/hyperflex-hx-se PX05) ries/eos-eol-notice-c51-2451489.html

Cisco UCS B200 M5 Blade Server 67 DISCONTINUED EOL PRODUCTS

Table 34 EOL Products (continued)

EOS option PID Description EOL Bulletin Link UCS-SD400GSAS3-EP 400 GB 2.5 inch Enterprise performance https://www.cisco.com/c/en/us/products/collate 12G SAS SSD(3X DWPD) ral/hyperconverged-infrastructure/hyperflex-hx-se ries/eos-eol-notice-c51-2451489.html UCS-SD32TSASS3-EP 3.2 TB 2.5 inch Enterprise performance https://www.cisco.com/c/en/us/products/collate 12G SAS SSD(3X DWPD) ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-741234.html NVMe UCSB-NVMELW-I500 500GB 2.5in U.2 Intel P4501 NVMe Med. https://www.cisco.com/c/en/us/products/collate Perf. Value Endurance ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-742509.html UCSB-NVMEXP-I375 375GB 2.5in Intel Optane NVMe Extreme https://www.cisco.com/c/en/us/products/collate Perf ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-742509.html UCSB-NVMELW-I1000 Cisco 2.5" U.2 1 TB Intel P4501 NVMe https://www.cisco.com/c/en/us/products/collate Med. Perf. Value Endurance ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-742509.html UCSB-NVMEHW-I1000 Cisco 2.5" U.2 1 TB Intel P4500 NVMe https://www.cisco.com/c/en/us/products/collate High Perf. Value Endurance ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-742509.html UCSB-NVMELW-I2000 Cisco 2.5" U.2 2 TB Intel P4501 NVMe https://www.cisco.com/c/en/us/products/collate Med. Perf. Value Endurance ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-742509.html UCSB-NVMEHW-I2000 Cisco 2.5" U.2 2.0 TB Intel P4600 NVMe https://www.cisco.com/c/en/us/products/collate High Perf. High Endur (Intel) ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-742823.html UCSB-NVMEHW-I1600 Cisco 2.5" U.2 1.6 TB Intel P4600 NVMe https://www.cisco.com/c/en/us/products/collate High Perf. High Endurance ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-742823.html UCSB-NVMEHW-I4000 Cisco 2.5" U.2 4 TB Intel P4500 NVMe https://www.cisco.com/c/en/us/products/collate High Perf. Value Endurance ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-742509.html UCSB-NVMEHW-I2TBV 2TB 2.5in U.2 Intel P4500 NVMe High https://www.cisco.com/c/en/us/products/collate Perf Value Endurance ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-742823.html UCSB-NVMEHW-I3200 3.2TB 2.5in U.2 Intel P4600 NVMe High https://www.cisco.com/c/en/us/products/collate Perf High Endurance ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-742823.html UCSB-NVMEHW-H3200 3.2TB 2.5in U.2 HGST SN200 NVMe High https://www.cisco.com/c/en/us/products/collate Perf. High Endurance ral/hyperconverged-infrastructure/hyperflex-hx-se ries/eos-eol-notice-c51-2451489.html UCSB-NVMEHW-H1600 Cisco 2.5" U.2 1.6 TB HGST SN200 NVMe https://www.cisco.com/c/en/us/products/collate High Perf. High Endurance ral/hyperconverged-infrastructure/hyperflex-hx-se ries/eos-eol-notice-c51-2451489.html SED UCS-SD480GBHBNK9 480GB Enterprise value SAS SSD (1X https://www.cisco.com/c/en/us/products/collate FWPD, SED) ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-742823.html

68 Cisco UCS B200 M5 Blade Server DISCONTINUED EOL PRODUCTS

Table 34 EOL Products (continued)

EOS option PID Description EOL Bulletin Link UCS-SD38TBHBNK9 3.8TB Enterprise value SAS SSD (1X https://www.cisco.com/c/en/us/products/collate FWPD, SED) ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-742823.html UCS-SD480G2HBNK9 480GB Enterprise value SAS SSD (1X https://www.cisco.com/c/en/us/products/collate FWPD, SED) FIPS 140-2 ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-743832.html MEMORY UCS-MR-X16G2RS-H 16GB DDR4-2666-MHz https://www.cisco.com/c/en/us/products/collate RDIMM/PC4-21300/dual rank/x4/1.2v ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-740780.html CPU UCS-CPU-I8280M Intel 8280M 2.7GHz/205W 28C/38.50MB https://www.cisco.com/c/en/us/products/collate 3DX DDR4 2TB 2933 MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-743832.html UCS-CPU-I8276M Intel 8276M 2.2GHz/165W 28C/38.50MB https://www.cisco.com/c/en/us/products/collate 3DX DDR4 2TB 2933 MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-743832.html UCS-CPU-I8260M Intel 8260M 2.4GHz/165W 24C/35.75MB https://www.cisco.com/c/en/us/products/collate 3DX DDR4 2TB 2933 MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-743832.html UCS-CPU-I5215M Intel 5215M 2.5GHz/85W 10C/13.75MB https://www.cisco.com/c/en/us/products/collate DCP DDR4 2TB 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-743832.html UCS-CPU-I6238M Intel 6238M 2.1GHz/140W 22C/30.25MB https://www.cisco.com/c/en/us/products/collate DCP DDR4 2TB 2933 MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-743832.html UCS-CPU-I6240M Intel 6240M 2.6GHz/150W 18C/24.75MB https://www.cisco.com/c/en/us/products/collate DCP DDR4 2TB 2933 MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-743832.html UCS-CPU-8180M 2.5 GHz 8180M/205W 28C/38.50MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-8176M 2.1 GHz 8176M/165W 28C/38.50MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-8170M 2.1 GHz 8170M/165W 26C/35.75MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-8160M 2.1 GHz 8160M/150W 24C/33MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-8180 2.5 GHz 8180/205W 28C/38.50MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-8176 2.1 GHz 8176/165W 28C/38.50MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html

Cisco UCS B200 M5 Blade Server 69 DISCONTINUED EOL PRODUCTS

Table 34 EOL Products (continued)

EOS option PID Description EOL Bulletin Link UCS-CPU-8170 2.1 GHz 8170/165W 26C/35.75MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-8168 2.7 GHz 8168/205W 24C/33MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-8164 2.0 GHz 8164/150W 26C/35.75MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-8160T 2.1 GHz 8160/150W 24C/33MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-8160 2.1 GHz 8160/150W 24C/33MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-8158 3.0 GHz 8158/150W 12C/24.75MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-8156 3.6 GHz 8156/105W 4C/16.50MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-8153 2.0 GHz 8153/125W 16C/22MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-6142M 2.6 GHz 6142M/150W 16C/22MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-6140M 2.3 GHz 6140M/140W 18C/24.75MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-6134M 3.2 GHz 6134M/130W 8C/24.75MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-6154 3.0 GHz 6154/200W 18C/24.75MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-6152 2.1 GHz 6152/140W 22C/30.25MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-6150 2.7 GHz 6150/165W 18C/24.75MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-6148 2.4 GHz 6148/150W 20C/27.50MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-6144 3.5 GHz 6144/150W 8C/24.75MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html

70 Cisco UCS B200 M5 Blade Server DISCONTINUED EOL PRODUCTS

Table 34 EOL Products (continued)

EOS option PID Description EOL Bulletin Link UCS-CPU-6142 2.6 GHz 6142/150W 16C/22MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-6140 2.3 GHz 6140/140W 18C/24.75MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-6138T 2.0 GHz 6138T/125W 20C/27.5MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-6138 2.0 GHz 6138/125W 20C/27.50MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-6136 3.0 GHz 6136/150W 12C/24.75MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-6134 3.2 GHz 6134/130W 8C/24.75MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-6132 2.6 GHz 6132/140W 14C/19.25MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-6130 2.1 GHz 6130/125W 16C/22MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-6128 3.4 GHz 6128/115W 6C/19.25MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-6126 2.6 GHz 6126/125W 12C/19.25MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-5122 3.6 GHz 5122/105W 4C/16.50MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2666MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-5120 2.2 GHz 5120/105W 14C/19.25MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2400MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-5118 2.3 GHz 5118/105W 12C/16.50MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2400MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-5117 2.0 GHz 5117/105W 14C/19.25MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2400MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-5115 2.4 GHz 5115/85W 10C/13.75MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2400MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-4116 2.1 GHz 4116/85W 12C/16.50MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2400MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html

Cisco UCS B200 M5 Blade Server 71 DISCONTINUED EOL PRODUCTS

Table 34 EOL Products (continued)

EOS option PID Description EOL Bulletin Link UCS-CPU-4114 2.2 GHz 4114/85W 10C/13.75MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2400MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-4112 2.6 GHz 4112/85W 4C/8.25MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2400MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-4110 2.1 GHz 4110/85W 8C/11MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2400MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-4108 1.8 GHz 4108/85W 8C/11MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2400MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-3106 1.7 GHz 3106/85W 8C/11MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2133MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html UCS-CPU-3104 1.7 GHz 3104/85W 6C/8.25MB https://www.cisco.com/c/en/us/products/collate Cache/DDR4 2133MHz ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-744580.html MEZZANINE ADAPTERS UCSB-F-H32003 UCS Blade PCIe/NVMe Storage Mezz https://www.cisco.com/c/en/us/products/collate 3200GB Medium Endurance ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-739513.html UCSB-F-H5607 UCS Blade PCIe/NVMe Storage Mezz https://www.cisco.com/c/en/us/products/collate 560GB High Endurance ral/servers-unified-computing/ucs-c-series-rack-se rvers/eos-eol-notice-c51-739513.html Microsoft Windows server MSWS-16-ST16C Windows Server 2016 Standard (16 https://www.cisco.com/c/en/us/products/servers Cores/2 VMs) -unified-computing/ucs-c-series-rack-servers/eos- eol-notice-c51-743145.html MSWS-16-ST24C Windows Server 2016 Standard (24 https://www.cisco.com/c/en/us/products/servers Cores/2 VMs) -unified-computing/ucs-c-series-rack-servers/eos- eol-notice-c51-743145.html MSWS-16-ST16C-NS Windows Server 2016 Standard (16 https://www.cisco.com/c/en/us/products/servers Cores/2 VMs) - No Cisco SVC -unified-computing/ucs-c-series-rack-servers/eos- eol-notice-c51-743145.html MSWS-16-ST24C-NS Windows Server 2016 Standard (24 https://www.cisco.com/c/en/us/products/servers Cores/2 VMs) - No Cisco SVC -unified-computing/ucs-c-series-rack-servers/eos- eol-notice-c51-743145.html MSWS-16-DC16C Windows Server 2016 Data Center (16 https://www.cisco.com/c/en/us/products/servers Cores/Unlimited VMs) -unified-computing/ucs-c-series-rack-servers/eos- eol-notice-c51-743145.html MSWS-16-DC24C Windows Server 2016 Data Center (24 https://www.cisco.com/c/en/us/products/servers Cores/Unlimited VMs) -unified-computing/ucs-c-series-rack-servers/eos- eol-notice-c51-743145.html MSWS-16-DC16C-NS Windows Server 2016 DC (16 https://www.cisco.com/c/en/us/products/servers Cores/Unlim VMs) - No Cisco SVC -unified-computing/ucs-c-series-rack-servers/eos- eol-notice-c51-743145.html

72 Cisco UCS B200 M5 Blade Server DISCONTINUED EOL PRODUCTS

Table 34 EOL Products (continued)

EOS option PID Description EOL Bulletin Link MSWS-16-DC24C-NS Windows Server 2016 DC (24 https://www.cisco.com/c/en/us/products/servers Cores/Unlim VMs) - No Cisco SVC -unified-computing/ucs-c-series-rack-servers/eos- eol-notice-c51-743145.html OS Media MSWS-16-ST16C-RM Windows Server 2016 Std (16 Cores/2 https://www.cisco.com/c/en/us/products/servers VMs) - Recovery Media -unified-computing/ucs-c-series-rack-servers/eos- eol-notice-c51-743145.html MSWS-16-ST24C-RM Windows Server 2016 Std (24 Cores/2 https://www.cisco.com/c/en/us/products/servers VMs) - Recovery Media -unified-computing/ucs-c-series-rack-servers/eos- eol-notice-c51-743145.html MSWS-16-DC16C-RM Windows Server 2016 DC (16 https://www.cisco.com/c/en/us/products/servers Cores/Unlim VMs) - Recovery Media -unified-computing/ucs-c-series-rack-servers/eos- eol-notice-c51-743145.html MSWS-16-DC24C-RM Windows Server 2016 DC (24 https://www.cisco.com/c/en/us/products/servers Cores/Unlim VMs) - Recovery Media -unified-computing/ucs-c-series-rack-servers/eos- eol-notice-c51-743145.html UCSM Software N20-FW015 UCS 5108 Blade Chassis FW Package https://www.cisco.com/c/en/us/products/collate 3.2(2) ral/servers-unified-computing/ucs-manager/eos-e ol-notice-c51-743144.html

Cisco UCS B200 M5 Blade Server 73 TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Dimensions and Weight

Table 35 UCS B200 M5 Dimensions and Weight

Parameter Value

Height 1.95 in. (50 mm)

Width 8.00 in.(203 mm)

Depth 24.4 in. (620 mm)

Weight ■ Base server weight = 9.51 lbs (4.31 kg) (no HDDs, no CPUs, no DIMMs, no mezzanine adapters or memory) ■ Minimally configured server weight = 11.29 lbs (5.12 kg) (no HDDs, 1 CPU, 8 DIMMs, VIC 1340 but no additional mezzanine adapter) ■ Fully configured server weight = 16 lbs (7.25 kg) (2 HDDs, 2 CPUs, 24 DIMMs, VIC 1340 and additional mezzanine adapter both populated)

Power Specifications For configuration-specific power specifications, use the Cisco UCS Power Calculator at: ■ http://ucspowercalc.cisco.com

NOTE: When using 256 GB DDR DIMMs (UCS-ML-256G8RT-H) in this server, the blade-level power capping must be set to 550 W. For information about blade-level power capping, see the Power Capping and Power Management chapter in the Cisco UCS Manager Server Management Guide for your release: Cisco UCS Manager Configuration Guides

74 Cisco UCS B200 M5 Blade Server

Cisco UCS B200 M5 Blade Server Spec Sheet (2024)

References

Top Articles
Latest Posts
Recommended Articles
Article information

Author: Wyatt Volkman LLD

Last Updated:

Views: 6397

Rating: 4.6 / 5 (46 voted)

Reviews: 85% of readers found this page helpful

Author information

Name: Wyatt Volkman LLD

Birthday: 1992-02-16

Address: Suite 851 78549 Lubowitz Well, Wardside, TX 98080-8615

Phone: +67618977178100

Job: Manufacturing Director

Hobby: Running, Mountaineering, Inline skating, Writing, Baton twirling, Computer programming, Stone skipping

Introduction: My name is Wyatt Volkman LLD, I am a handsome, rich, comfortable, lively, zealous, graceful, gifted person who loves writing and wants to share my knowledge and understanding with you.